Specification 200~230V
| Drive Type (SV_ _ _iG5-_) | 004-1 | 008-1 | 015-1 | 004-2 | 008-2 | 015-2 | 022-2 | 037-2 | 040-2 | |
| Motor Rating | [HP] | 0.5 | 1 | 2 | 0.5 | 1 | 2 | 3 | 5 | 5.4 | 
| [kW] | 0.37 | 0.75 | 1.5 | 0.37 | 0.75 | 1.5 | 2.2 | 3.7 | 4 | |
| 
 Output ratings | Capacity[kVA] | 1.1 | 1.9 | 3 | 1.1 | 1.9 | 3 | 4.5 | 6.1 | 6.5 | 
| FLA[A] | 3 | 5 | 8 | 3 | 5 | 8 | 12 | 16 | 17 | |
| Frequency | 0 ~ 400 Hz | |||||||||
| Voltage | 200 ~ 230V | |||||||||
| Input ratings | Voltage | 1 phase 200 ~ 230 V( 10%) 3 phase 200 ~ 230 V( 10%) | ||||||||
| Frequency | 50 ~ 60 Hz ( 5%) 50 ~ 60 Hz ( 5%) | |||||||||
| Weight[kg] | 
 | 1.2 | 1.8 | 2.1 | 1.2 | 1.2 | 1.8 | 2.1 | 2.2 | 2.2 | 
| 
 | Braking circuit | On board | ||||||||
| Average braking torque | 20% (with optional external braking resistor : 100%, 150%) | |||||||||
| Braking torque | Max.continuous braking time | 15 seconds | ||||||||
| Max. duty | 0 ~ 30 % ED | |||||||||
| Cooling method | 
 | Forced air cooling Natura | ||||||||
| Enclosure | 
 | IP00 | ||||||||
Specification 380~460V
| Drive Type (SV_ _ _iG5-_) | 004-4 | 008-4 | 015-4 | 022-4 | 037-4 | 040-4 | |||
| Motor Rating | [HP] | 0.5 | 1 | 2 | 3 | 5 | 5.4 | ||
| [kW] | 0.37 | 0.75 | 1.5 | 2.2 | 3.7 | 4 | |||
| 
 Output ratings | Capacity[kVA] | 1.1 | 1.9 | 3 | 4.5 | 6.1 | 6.5 | ||
| FLA[A] | 1.1 | 2.5 | 4 | 6 | 8 | 9 | |||
| Input ratings | Voltage | 3 phase 380 ~ 460 V( 10%) | |||||||
| Frequency | 50 ~ 60 Hz ( 5%) | ||||||||
| Weight[kg] | Weight [kg] | 1.7 | 1.7 | 1.8 | 2.1 | 2.2 | 2.2 | ||
| 
 | Braking circuit | On board | |||||||
| 
 Braking torque | Average braking torque | 20% (with optional external braking resistor : 100%, 150%) | |||||||
| Max. continuous braking time | 15 seconds | ||||||||
| Max. duty | 0 ~ 30 % ED | ||||||||
| Cooling method | Forced air cooling | ||||||||
| Enclosure | IP00 | ||||||||
| 
 
 Control 
 | Control method | V/F control | |||||||
| Frequency setting resolution | Digital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Analog reference : 0.03 Hz / 50 Hz | ||||||||
| Frequency accuracy | Digital : 0.01% of max. output frequency Analog : 0.1% of max. output frequency | ||||||||
| V/F ratio | Linear, Square pattern, User V/F | ||||||||
| Overload capacity | 150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time) | ||||||||
| Torque boost | Manual torque boost (0 ~ 15 %), Auto torque boost | ||||||||
| 
 
 
 
 
 operation | Input signal | Operation method | Keypad / terminal / communication operation | ||||||
| Frequency setting | Analog : 0 ~ 10V / 4 ~ 20 mA Digital : keypad | ||||||||
| Start signal | Forward, Reverse | ||||||||
| Multi-step | Up to 8 speeds can be set (use multi-function terminal) | ||||||||
| Multi-step accel/decel time | 0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal) | ||||||||
| Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, Minimum | |||||||||
| Emergency stop | Interrupts the output of the drive | ||||||||
| Jog | Jog operation | ||||||||
| Fault reset | Resets fault when protective function is active | ||||||||
| Output signal | Operation status | Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop, | |||||||
| constant speed, speed searching | |||||||||
| Fault output | Contact output (30A,30C,30B) - AC250V 1A, DC30V 1A | ||||||||
| Indicator | Choose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V) | ||||||||
| Operation function | DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention, | |
| auto restart, PID control | ||
| 
 Protective function | Drive trip | Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss, | 
| 
 | input/output mis-wiring, overload protection, communication error, loss of speed command, hardware faul | |
| Inverter alarm | Stall prevention, overload alarm | |
| Momentary power loss | Less than 15 msec : continuous operation, more than 15 msec : auto restart possible | |
| Display Keypad | Operation information | Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage | 
| Trip information | Indicates the fault when the protection function activates, memorizes up to 5 faults | |
| 
 Environment | Ambient temperature | -10 °C ~ 40 °C | 
| Storage temperature | -20 °C ~ 65 °C | |
| Ambient humidity | 90 % RH max.(Non condensing) | |
| Altitude . Vibration | Below 1,000 m below 5.9m/sec2(=0.6g) | |
| Application site | No corrosive gas, combustible gas, oil mist, or dust | |