Specification 200~230V

Drive Type (SV_ _ _iG5-_)

004-1

008-1

015-1

004-2

008-2

015-2

022-2

037-2

040-2

Motor Rating

[HP]

0.5

1

2

0.5

1

2

3

5

5.4

[kW]

0.37

0.75

1.5

0.37

0.75

1.5

2.2

3.7

4

 

Output ratings

Capacity[kVA]

1.1

1.9

3

1.1

1.9

3

4.5

6.1

6.5

FLA[A]

3

5

8

3

5

8

12

16

17

Frequency

                           0 ~ 400 Hz

Voltage

                           200 ~ 230V

Input ratings

Voltage

1 phase 200 ~ 230 V( 10%)              3 phase 200 ~ 230 V( 10%)

Frequency

50 ~ 60 Hz ( 5%)                        50 ~ 60 Hz ( 5%)

Weight[kg]

 

1.2

1.8

2.1

1.2

1.2

1.8

2.1

2.2

2.2

 

Braking circuit

                            On board

Average braking torque

20% (with optional external braking resistor : 100%, 150%)

Braking torque

Max.continuous braking time

                          15 seconds

Max. duty

                          0 ~ 30 % ED

Cooling method

 

                          Forced air cooling Natura

Enclosure

 

                          IP00

Specification 380~460V

Drive Type (SV_ _ _iG5-_)

004-4

008-4

015-4

022-4

037-4

040-4

Motor Rating

[HP]

0.5

1

2

3

5

5.4

[kW]

0.37

0.75

1.5

2.2

3.7

4

 

Output ratings

Capacity[kVA]

1.1

1.9

3

4.5

6.1

6.5

FLA[A]

1.1

2.5

4

6

8

9

Input ratings

Voltage

3 phase 380 ~ 460 V( 10%)

Frequency

50 ~ 60 Hz ( 5%)

Weight[kg]

Weight [kg]

1.7

1.7

1.8

2.1

2.2

2.2

 

Braking circuit

On board

 

Braking torque

Average braking torque

20% (with optional external braking resistor : 100%, 150%)

Max. continuous braking time

15 seconds

Max. duty

0 ~ 30 % ED

Cooling method

Forced air cooling

Enclosure

IP00

 

 

Control

 

Control method

V/F control

Frequency setting resolution

Digital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Analog reference : 0.03 Hz / 50 Hz

Frequency accuracy

Digital : 0.01% of max. output frequency Analog : 0.1% of max. output frequency

V/F ratio

Linear, Square pattern, User V/F

Overload capacity

150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time)

Torque boost

Manual torque boost (0 ~ 15 %), Auto torque boost

 

 

 

 

 

operation

Input signal

Operation method

Keypad / terminal / communication operation

Frequency setting

Analog : 0 ~ 10V / 4 ~ 20 mA Digital : keypad

Start signal

Forward, Reverse

Multi-step

Up to 8 speeds can be set (use multi-function terminal)

Multi-step accel/decel time

0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal)

Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, Minimum

Emergency stop

Interrupts the output of the drive

Jog

Jog operation

Fault reset

Resets fault when protective function is active

Output signal

Operation status

Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop,

constant speed, speed searching

Fault output

Contact output (30A,30C,30B) - AC250V 1A, DC30V 1A

Indicator

Choose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V)

                   

 

Operation

function

DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention,

                  auto restart, PID control

 

Protective

function

Drive trip

Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss,

 

input/output mis-wiring, overload protection, communication error, loss of speed command, hardware faul

Inverter alarm

Stall prevention, overload alarm

Momentary power loss

Less than 15 msec : continuous operation, more than 15 msec : auto restart possible

Display

Keypad

Operation information

Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage

Trip information

Indicates the fault when the protection function activates, memorizes up to 5 faults

 

Environment

Ambient temperature

                  -10 °C ~ 40 °C

Storage temperature

          -20 °C ~ 65 °C

Ambient humidity

          90 % RH max.(Non condensing)

Altitude . Vibration

          Below 1,000 m below 5.9m/sec2(=0.6g)

Application site

          No corrosive gas, combustible gas, oil mist, or dust