VFD2800CH43C-21 Delta CH2000 input AC 3phase 380V 550A 0~600Hz 280KW 375HP Inverter VFD AC Motor Drive with Keypad New
- Model: VFD2800CH43C-21
- Shipping Weight: 240Kg
- In Stock:20
- Manufactured by: Delta
VFD2800CH43C-21 Delta CH2000 input AC 3phase 380V 550A 0~600Hz 280KW 375HP Inverter VFD AC Motor Drive with Keypad New
VFD2800CH43C-21
Features
Using new drive technology, Delta presents you with its next generation CH2000 Series AC Motor Drive. Providing high performance with robust design the CH2000 is equipped with a larger starting torque and high overload capability to fulfill the needs of heavy load and impact loading applications.
Specifications
Super Heavy Load (SHD)
-Overload ability: rated current of 150% up to 60 seconds, 200% up to 3 seconds
-Starting torque: above 200% at 0.5Hz in normal conditions, up to 200% at 0Hz in FOC+PG mode
-Output frequency: 0.00~600.00Hz (for model above 90kW: 0.00~400Hz)
-Induction motor and synchronous motor control
-Built-in PLC program capacity: 10K steps
-Noise reduction
Production Specifications
230V Series
Frame Size |
A |
B |
C |
||||||||
Model VFDxxxCH23A-21 |
007 |
015 |
022 |
037 |
055 |
075 |
110 |
150 |
185 |
||
Applicable Motor Output (kW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
||
Applicable Motor Output (hp) |
1 |
2 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
||
Output Rating |
Super Heavy Duty |
Rated Output capacity(kVA) |
2.0 |
3.2 |
4.4 |
6.8 |
10 |
13 |
20 |
26 |
30 |
Rated Output Current (A) |
5 |
8 |
11 |
17 |
25 |
33 |
49 |
65 |
75 |
||
Carrier Frequency (kHz) |
5~15kHz |
||||||||||
Overload Tolerance |
Rated output current is 150 % for 60 seconds; 200% for 3 seconds |
||||||||||
Input Rating |
Input Current (A) Super Heavy Duty |
6.4 |
12 |
16 |
20 |
28 |
36 |
52 |
72 |
83 |
|
Rated Voltage/Frequency |
3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz |
||||||||||
Operating Voltage Range |
170~265Vac |
||||||||||
Frequency Tolerance |
47~63Hz |
||||||||||
AC Drive Weight |
2.6± 0.3Kg |
5.4± 1Kg |
9.8± 1.5Kg |
||||||||
Cooling method |
Natural Cooling |
Fan cooling |
|||||||||
Braking Chopper |
Frame A to C (built-in); Frame D and above (optional) |
||||||||||
DC reactor |
Frame A to C (optional); Frame D and above (built-in) |
||||||||||
EMI Filter |
Optional |
||||||||||
EMC-COP01 |
Optional |
Frame Size |
D |
E |
F |
|||||
Model VFDxxxCH23A-21 |
200 |
300 |
370 |
450 |
550 |
750 |
||
Applicable Motor Output (kW) |
22 |
22 |
30 |
37 |
45 |
55 |
||
Applicable Motor Output (hp) |
30 |
40 |
50 |
60 |
75 |
100 |
||
Output Rating |
Super Heavy DUTY |
Rate Output Capacity (kVA) |
36 |
48 |
58 |
72 |
86 |
102 |
Rated Output Current (A) |
90 |
120 |
146 |
180 |
215 |
255 |
||
Carrier Frequency (kHz) |
5~15kHz |
|||||||
Overload Tolerance |
Rated output current is 150 % for 60 seconds; 200% for 3 seconds |
|||||||
Input Rating |
Input Current (A) |
93 |
124 |
143 |
171 |
206 |
245 |
|
Rated Voltage/Frequency |
3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz |
|||||||
Operating Voltage Range |
170~265Vac |
|||||||
Frequency Tolerance |
47~63Hz |
|||||||
AC Drive Weight |
38.5+- 1.5Kg |
64.8± 1.5Kg |
86.5± 1.5Kg |
|||||
Cooling method |
Fan Cooling |
|||||||
Braking Chopper |
Frame A to C (built-in); Frame D and above (optional) |
|||||||
DC reactor |
Frame A to C (optional); Frame D and above (built-in) |
|||||||
EMI Filter |
Optional |
|||||||
EMC-COP01 |
Optional |
460V Series
Frame Size |
A |
B |
C |
||||||||||
Model VFDxxxCH43A-21 VFDxxxCH4EA-21 |
007 |
015 |
022 |
037 |
055 |
075 |
110 |
150 |
185 |
220 |
300 |
||
Applicable Motor Output (kW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
||
Applicable Motor Output (hp) |
1 |
2 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
||
Output Rating |
Super Heavy Duty |
Rate Output Capacity (kVA) |
2.4 |
3.2 |
4.8 |
7.2 |
9.6 |
14 |
19 |
25 |
30 |
36 |
48 |
Rated Output Current (A) |
3.0 |
40. |
6.0 |
9.0 |
12 |
18 |
24 |
32 |
38 |
45 |
60 |
||
Carrier Frequency (kHz) |
5~15kHz |
||||||||||||
Overload Tolerance |
Rated output current is 150 % for 60 seconds; 200% for 3 seconds |
||||||||||||
Input Rating |
Input Current (A) Normal Duty |
4.3 |
5.9 |
8.7 |
14 |
17 |
20 |
26 |
35 |
40 |
47 |
63 |
|
Rated Voltage/Frequency |
3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz |
||||||||||||
Operating Voltage Range |
323~528Vac |
||||||||||||
Frequency Tolerance |
47~63Hz |
||||||||||||
AC Drive Weight |
2.6± 0.3Kg |
5.4± 1Kg |
9.8± 2Kg |
||||||||||
Cooling method |
Natural cooling |
Fan cooling |
|||||||||||
Braking Chopper |
Frame A to C (built-in); Frame D and above (optional) |
||||||||||||
DC reactor |
Frame A to C (optional); Frame D and above (built-in) |
||||||||||||
EMI Filter |
Frame A ~ C, VFDxxxxCH4EA-21, EMI filter built-in Frame A ~ C, VFDxxxxCH43A-21, No EMI filter |
||||||||||||
EMC-COP01 |
Optional |
Frame Size |
D |
E |
F |
G |
H |
||||||||||
Model VFDxxxxCH43A-xx VFD2800CH43C-00/-21 |
370 |
450 |
550 |
750 |
900 |
1100 |
1320 |
1600 |
1850 |
2200 |
2800 |
||||
Applicable Motor Output (kW) |
37 |
45 |
55 |
75 |
90 |
110 |
132 |
160 |
185 |
220 |
280 |
||||
Applicable Motor Output (hp) |
50 |
60 |
75 |
100 |
125 |
150 |
175 |
215 |
250 |
300 |
375 |
||||
Output Rating |
Super Heavy DUTY |
Rate Output Capacity (kVA) |
58 |
73 |
88 |
120 |
143 |
175 |
207 |
247 |
295 |
359 |
438 |
||
Rated Output Current (A) |
73 |
91 |
110 |
150 |
180 |
220 |
250 |
310 |
370 |
450 |
550 |
||||
Carrier Frequency (kHz) |
5~15kHz |
4~10kHz |
|||||||||||||
Overload Tolerance |
Rated output current is 150 % for 60 seconds; 200% for 3 seconds |
||||||||||||||
Input Rating |
Input Current (A) Normal Duty |
74 |
101 |
114 |
157 |
167 |
207 |
240 |
300 |
380 |
400 |
494 |
|||
Rated Voltage/Frequency |
3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz |
||||||||||||||
Operating Voltage Range |
323~528Vac |
||||||||||||||
Frequency Tolerance |
47~63Hz |
||||||||||||||
AC Drive Weight |
38.5± 1.5Kg |
64.8± 1.5Kg |
86.5± 1.5Kg |
134± 4Kg |
228Kg |
||||||||||
Cooling method |
Fan cooling |
||||||||||||||
Braking Chopper |
Frame D and above (optional) |
||||||||||||||
DC reactor |
Frame D and above (built-in) |
||||||||||||||
EMI Filter |
Frame D and above (optional) |
||||||||||||||
EMC-COP01 |
Optional |
||||||||||||||
Applications
Crane, processing machinery, printing machinery
Wiring