VFD2200CH43A-21
Features
Using new drive technology, Delta presents you with its next generation CH2000 Series AC Motor Drive. Providing high performance with robust design the CH2000 is equipped with a larger starting torque and high overload capability to fulfill the needs of heavy load and impact loading applications.
Specifications
Super Heavy Load (SHD)
-Overload ability: rated current of 150% up to 60 seconds, 200% up to 3 seconds
-Starting torque: above 200% at 0.5Hz in normal conditions, up to 200% at 0Hz in FOC+PG mode
-Output frequency: 0.00~600.00Hz (for model above 90kW: 0.00~400Hz)
-Induction motor and synchronous motor control
-Built-in PLC program capacity: 10K steps
-Noise reduction
Production Specifications
230V Series
| Frame Size | A | B | C | ||||||||
| Model VFDxxxCH23A-21 | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | ||
| Applicable Motor Output (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | ||
| Applicable Motor Output (hp) | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | ||
| Output Rating | Super Heavy Duty | Rated Output capacity(kVA) | 2.0 | 3.2 | 4.4 | 6.8 | 10 | 13 | 20 | 26 | 30 | 
| Rated Output Current (A) | 5 | 8 | 11 | 17 | 25 | 33 | 49 | 65 | 75 | ||
| Carrier Frequency (kHz) | 5~15kHz | ||||||||||
| Overload Tolerance | Rated output current is 150 % for 60 seconds; 200% for 3 seconds | ||||||||||
| Input Rating | Input Current (A) Super Heavy Duty | 6.4 | 12 | 16 | 20 | 28 | 36 | 52 | 72 | 83 | |
| Rated Voltage/Frequency | 3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz | ||||||||||
| Operating Voltage Range | 170~265Vac | ||||||||||
| Frequency Tolerance | 47~63Hz | ||||||||||
| AC Drive Weight | 2.6± 0.3Kg | 5.4± 1Kg | 9.8± 1.5Kg | ||||||||
| Cooling method | Natural Cooling | Fan cooling | |||||||||
| Braking Chopper | Frame A to C (built-in); Frame D and above (optional) | ||||||||||
| DC reactor | Frame A to C (optional); Frame D and above (built-in) | ||||||||||
| EMI Filter | Optional | ||||||||||
| EMC-COP01 | Optional | ||||||||||
| Frame Size | D | E | F | |||||
| Model VFDxxxCH23A-21 | 200 | 300 | 370 | 450 | 550 | 750 | ||
| Applicable Motor Output (kW) | 22 | 22 | 30 | 37 | 45 | 55 | ||
| Applicable Motor Output (hp) | 30 | 40 | 50 | 60 | 75 | 100 | ||
| Output Rating | Super Heavy DUTY | Rate Output Capacity (kVA) | 36 | 48 | 58 | 72 | 86 | 102 | 
| Rated Output Current (A) | 90 | 120 | 146 | 180 | 215 | 255 | ||
| Carrier Frequency (kHz) | 5~15kHz | |||||||
| Overload Tolerance | Rated output current is 150 % for 60 seconds; 200% for 3 seconds | |||||||
| Input Rating | Input Current (A) | 93 | 124 | 143 | 171 | 206 | 245 | |
| Rated Voltage/Frequency | 3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz | |||||||
| Operating Voltage Range | 170~265Vac | |||||||
| Frequency Tolerance | 47~63Hz | |||||||
| AC Drive Weight | 38.5+- 1.5Kg | 64.8± 1.5Kg | 86.5± 1.5Kg | |||||
| Cooling method | Fan Cooling | |||||||
| Braking Chopper | Frame A to C (built-in); Frame D and above (optional) | |||||||
| DC reactor | Frame A to C (optional); Frame D and above (built-in) | |||||||
| EMI Filter | Optional | |||||||
| EMC-COP01 | Optional | |||||||
460V Series
| Frame Size | A | B | C | ||||||||||
| Model VFDxxxCH43A-21 VFDxxxCH4EA-21 | 007 | 015 | 022 | 037 | 055 | 075 | 110 | 150 | 185 | 220 | 300 | ||
| Applicable Motor Output (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | ||
| Applicable Motor Output (hp) | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | ||
| Output Rating | Super Heavy Duty | Rate Output Capacity (kVA) | 2.4 | 3.2 | 4.8 | 7.2 | 9.6 | 14 | 19 | 25 | 30 | 36 | 48 | 
| Rated Output Current (A) | 3.0 | 40. | 6.0 | 9.0 | 12 | 18 | 24 | 32 | 38 | 45 | 60 | ||
| Carrier Frequency (kHz) | 5~15kHz | ||||||||||||
| Overload Tolerance | Rated output current is 150 % for 60 seconds; 200% for 3 seconds | ||||||||||||
| Input Rating | Input Current (A) Normal Duty | 4.3 | 5.9 | 8.7 | 14 | 17 | 20 | 26 | 35 | 40 | 47 | 63 | |
| Rated Voltage/Frequency | 3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz | ||||||||||||
| Operating Voltage Range | 323~528Vac | ||||||||||||
| Frequency Tolerance | 47~63Hz | ||||||||||||
| AC Drive Weight | 2.6± 0.3Kg | 5.4± 1Kg | 9.8± 2Kg | ||||||||||
| Cooling method | Natural cooling | Fan cooling | |||||||||||
| Braking Chopper | Frame A to C (built-in); Frame D and above (optional) | ||||||||||||
| DC reactor | Frame A to C (optional); Frame D and above (built-in) | ||||||||||||
| EMI Filter | Frame A ~ C, VFDxxxxCH4EA-21, EMI filter built-in Frame A ~ C, VFDxxxxCH43A-21, No EMI filter | ||||||||||||
| EMC-COP01 | Optional | ||||||||||||
| Frame Size | D | E | F | G | H | ||||||||||
| Model VFDxxxxCH43A-xx VFD2800CH43C-00/-21 | 370 | 450 | 550 | 750 | 900 | 1100 | 1320 | 1600 | 1850 | 2200 | 2800 | ||||
| Applicable Motor Output (kW) | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 220 | 280 | ||||
| Applicable Motor Output (hp) | 50 | 60 | 75 | 100 | 125 | 150 | 175 | 215 | 250 | 300 | 375 | ||||
| Output Rating | Super Heavy DUTY | Rate Output Capacity (kVA) | 58 | 73 | 88 | 120 | 143 | 175 | 207 | 247 | 295 | 359 | 438 | ||
| Rated Output Current (A) | 73 | 91 | 110 | 150 | 180 | 220 | 250 | 310 | 370 | 450 | 550 | ||||
| Carrier Frequency (kHz) | 5~15kHz | 4~10kHz | |||||||||||||
| Overload Tolerance | Rated output current is 150 % for 60 seconds; 200% for 3 seconds | ||||||||||||||
| Input Rating | Input Current (A) Normal Duty | 74 | 101 | 114 | 157 | 167 | 207 | 240 | 300 | 380 | 400 | 494 | |||
| Rated Voltage/Frequency | 3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz | ||||||||||||||
| Operating Voltage Range | 323~528Vac | ||||||||||||||
| Frequency Tolerance | 47~63Hz | ||||||||||||||
| AC Drive Weight | 38.5± 1.5Kg | 64.8± 1.5Kg | 86.5± 1.5Kg | 134± 4Kg | 228Kg | ||||||||||
| Cooling method | Fan cooling | ||||||||||||||
| Braking Chopper | Frame D and above (optional) | ||||||||||||||
| DC reactor | Frame D and above (built-in) | ||||||||||||||
| EMI Filter | Frame D and above (optional) | ||||||||||||||
| EMC-COP01 | Optional | ||||||||||||||
Applications
Crane, processing machinery, printing machinery
Wiring Diagram