VFD1320CH43A-21 Delta CH2000 input AC 3phase 380V 250A 0~600Hz 132kW 175HP Inverter VFD AC Motor Drive with Keypad New
- Model: VFD1320CH43A-21
 - Shipping Weight: 100Kg
 - In Stock:20
 - Manufactured by: Delta
 




                                        0 reviews                                         
                                    VFD1320CH43A-21 Delta CH2000 input AC 3phase 380V 250A 0~600Hz 132kW 175HP Inverter VFD AC Motor Drive with Keypad New
VFD1320CH43A-21
Features
Using new drive technology, Delta presents you with its next generation CH2000 Series AC Motor Drive. Providing high performance with robust design the CH2000 is equipped with a larger starting torque and high overload capability to fulfill the needs of heavy load and impact loading applications.
Specifications
Super Heavy Load (SHD)
-Overload ability: rated current of 150% up to 60 seconds, 200% up to 3 seconds
-Starting torque: above 200% at 0.5Hz in normal conditions, up to 200% at 0Hz in FOC+PG mode
-Output frequency: 0.00~600.00Hz (for model above 90kW: 0.00~400Hz)
-Induction motor and synchronous motor control
-Built-in PLC program capacity: 10K steps
-Noise reduction
Production Specifications
230V Series
| 
 Frame Size  | 
 A  | 
 B  | 
 C  | 
||||||||
| 
 Model VFDxxxCH23A-21  | 
 007  | 
 015  | 
 022  | 
 037  | 
 055  | 
 075  | 
 110  | 
 150  | 
 185  | 
||
| 
 Applicable Motor Output (kW)  | 
 0.75  | 
 1.5  | 
 2.2  | 
 3.7  | 
 5.5  | 
 7.5  | 
 11  | 
 15  | 
 18.5  | 
||
| 
 Applicable Motor Output (hp)  | 
 1  | 
 2  | 
 3  | 
 5  | 
 7.5  | 
 10  | 
 15  | 
 20  | 
 25  | 
||
| 
 Output Rating  | 
 Super Heavy Duty  | 
 Rated Output capacity(kVA)  | 
 2.0  | 
 3.2  | 
 4.4  | 
 6.8  | 
 10  | 
 13  | 
 20  | 
 26  | 
 30  | 
| 
 Rated Output Current (A)  | 
 5  | 
 8  | 
 11  | 
 17  | 
 25  | 
 33  | 
 49  | 
 65  | 
 75  | 
||
| 
 Carrier Frequency (kHz)  | 
 5~15kHz  | 
||||||||||
| 
 Overload Tolerance  | 
 Rated output current is 150 % for 60 seconds; 200% for 3 seconds  | 
||||||||||
| 
 Input Rating  | 
 Input Current (A) Super Heavy Duty  | 
 6.4  | 
 12  | 
 16  | 
 20  | 
 28  | 
 36  | 
 52  | 
 72  | 
 83  | 
|
| 
 Rated Voltage/Frequency  | 
 3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz  | 
||||||||||
| 
 Operating Voltage Range  | 
 170~265Vac  | 
||||||||||
| 
 Frequency Tolerance  | 
 47~63Hz  | 
||||||||||
| 
 AC Drive Weight  | 
 2.6± 0.3Kg  | 
 5.4± 1Kg  | 
 9.8± 1.5Kg  | 
||||||||
| 
 Cooling method  | 
 Natural Cooling  | 
 Fan cooling  | 
|||||||||
| 
 Braking Chopper  | 
 Frame A to C (built-in); Frame D and above (optional)  | 
||||||||||
| 
 DC reactor  | 
 Frame A to C (optional); Frame D and above (built-in)  | 
||||||||||
| 
 EMI Filter  | 
 Optional  | 
||||||||||
| 
 EMC-COP01  | 
 Optional  | 
||||||||||
| 
 Frame Size  | 
 D  | 
 E  | 
 F  | 
|||||
| 
 Model VFDxxxCH23A-21  | 
 200  | 
 300  | 
 370  | 
 450  | 
 550  | 
 750  | 
||
| 
 Applicable Motor Output (kW)  | 
 22  | 
 22  | 
 30  | 
 37  | 
 45  | 
 55  | 
||
| 
 Applicable Motor Output (hp)  | 
 30  | 
 40  | 
 50  | 
 60  | 
 75  | 
 100  | 
||
| 
 Output Rating  | 
 Super Heavy DUTY  | 
 Rate Output Capacity (kVA)  | 
 36  | 
 48  | 
 58  | 
 72  | 
 86  | 
 102  | 
| 
 Rated Output Current (A)  | 
 90  | 
 120  | 
 146  | 
 180  | 
 215  | 
 255  | 
||
| 
 Carrier Frequency (kHz)  | 
 5~15kHz  | 
|||||||
| 
 Overload Tolerance  | 
 Rated output current is 150 % for 60 seconds; 200% for 3 seconds  | 
|||||||
| 
 Input Rating  | 
 Input Current (A)  | 
 93  | 
 124  | 
 143  | 
 171  | 
 206  | 
 245  | 
|
| 
 Rated Voltage/Frequency  | 
 3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz  | 
|||||||
| 
 Operating Voltage Range  | 
 170~265Vac  | 
|||||||
| 
 Frequency Tolerance  | 
 47~63Hz  | 
|||||||
| 
 AC Drive Weight  | 
 38.5+- 1.5Kg  | 
 64.8± 1.5Kg  | 
 86.5± 1.5Kg  | 
|||||
| 
 Cooling method  | 
 Fan Cooling  | 
|||||||
| 
 Braking Chopper  | 
 Frame A to C (built-in); Frame D and above (optional)  | 
|||||||
| 
 DC reactor  | 
 Frame A to C (optional); Frame D and above (built-in)  | 
|||||||
| 
 EMI Filter  | 
 Optional  | 
|||||||
| 
 EMC-COP01  | 
 Optional  | 
|||||||
460V Series
| 
 Frame Size  | 
 A  | 
 B  | 
 C  | 
||||||||||
| 
 Model VFDxxxCH43A-21 VFDxxxCH4EA-21  | 
 007  | 
 015  | 
 022  | 
 037  | 
 055  | 
 075  | 
 110  | 
 150  | 
 185  | 
 220  | 
 300  | 
||
| 
 Applicable Motor Output (kW)  | 
 0.75  | 
 1.5  | 
 2.2  | 
 3.7  | 
 5.5  | 
 7.5  | 
 11  | 
 15  | 
 18.5  | 
 22  | 
 30  | 
||
| 
 Applicable Motor Output (hp)  | 
 1  | 
 2  | 
 3  | 
 5  | 
 7.5  | 
 10  | 
 15  | 
 20  | 
 25  | 
 30  | 
 40  | 
||
| 
 Output Rating  | 
 Super Heavy Duty  | 
 Rate Output Capacity (kVA)  | 
 2.4  | 
 3.2  | 
 4.8  | 
 7.2  | 
 9.6  | 
 14  | 
 19  | 
 25  | 
 30  | 
 36  | 
 48  | 
| 
 Rated Output Current (A)  | 
 3.0  | 
 40.  | 
 6.0  | 
 9.0  | 
 12  | 
 18  | 
 24  | 
 32  | 
 38  | 
 45  | 
 60  | 
||
| 
 Carrier Frequency (kHz)  | 
 5~15kHz  | 
||||||||||||
| 
 Overload Tolerance  | 
 Rated output current is 150 % for 60 seconds; 200% for 3 seconds  | 
||||||||||||
| 
 Input Rating  | 
 Input Current (A) Normal Duty  | 
 4.3  | 
 5.9  | 
 8.7  | 
 14  | 
 17  | 
 20  | 
 26  | 
 35  | 
 40  | 
 47  | 
 63  | 
|
| 
 Rated Voltage/Frequency  | 
 3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz  | 
||||||||||||
| 
 Operating Voltage Range  | 
 323~528Vac  | 
||||||||||||
| 
 Frequency Tolerance  | 
 47~63Hz  | 
||||||||||||
| 
 AC Drive Weight  | 
 2.6± 0.3Kg  | 
 5.4± 1Kg  | 
 9.8± 2Kg  | 
||||||||||
| 
 Cooling method  | 
 Natural cooling  | 
 Fan cooling  | 
|||||||||||
| 
 Braking Chopper  | 
 Frame A to C (built-in); Frame D and above (optional)  | 
||||||||||||
| 
 DC reactor  | 
 Frame A to C (optional); Frame D and above (built-in)  | 
||||||||||||
| 
 EMI Filter  | 
 Frame A ~ C, VFDxxxxCH4EA-21, EMI filter built-in Frame A ~ C, VFDxxxxCH43A-21, No EMI filter  | 
||||||||||||
| 
 EMC-COP01  | 
 Optional  | 
||||||||||||
| 
 Frame Size  | 
 D  | 
 E  | 
 F  | 
 G  | 
 H  | 
||||||||||
| 
 Model VFDxxxxCH43A-xx VFD2800CH43C-00/-21  | 
 370  | 
 450  | 
 550  | 
 750  | 
 900  | 
 1100  | 
 1320  | 
 1600  | 
 1850  | 
 2200  | 
 2800  | 
||||
| 
 Applicable Motor Output (kW)  | 
 37  | 
 45  | 
 55  | 
 75  | 
 90  | 
 110  | 
 132  | 
 160  | 
 185  | 
 220  | 
 280  | 
||||
| 
 Applicable Motor Output (hp)  | 
 50  | 
 60  | 
 75  | 
 100  | 
 125  | 
 150  | 
 175  | 
 215  | 
 250  | 
 300  | 
 375  | 
||||
| 
 Output Rating  | 
 Super Heavy DUTY  | 
 Rate Output Capacity (kVA)  | 
 58  | 
 73  | 
 88  | 
 120  | 
 143  | 
 175  | 
 207  | 
 247  | 
 295  | 
 359  | 
 438  | 
||
| 
 Rated Output Current (A)  | 
 73  | 
 91  | 
 110  | 
 150  | 
 180  | 
 220  | 
 250  | 
 310  | 
 370  | 
 450  | 
 550  | 
||||
| 
 Carrier Frequency (kHz)  | 
 5~15kHz  | 
 4~10kHz  | 
|||||||||||||
| 
 Overload Tolerance  | 
 Rated output current is 150 % for 60 seconds; 200% for 3 seconds  | 
||||||||||||||
| 
 Input Rating  | 
 Input Current (A) Normal Duty  | 
 74  | 
 101  | 
 114  | 
 157  | 
 167  | 
 207  | 
 240  | 
 300  | 
 380  | 
 400  | 
 494  | 
|||
| 
 Rated Voltage/Frequency  | 
 3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz  | 
||||||||||||||
| 
 Operating Voltage Range  | 
 323~528Vac  | 
||||||||||||||
| 
 Frequency Tolerance  | 
 47~63Hz  | 
||||||||||||||
| 
 AC Drive Weight  | 
 38.5± 1.5Kg  | 
 64.8± 1.5Kg  | 
 86.5± 1.5Kg  | 
 134± 4Kg  | 
 228Kg  | 
||||||||||
| 
 Cooling method  | 
 Fan cooling  | 
||||||||||||||
| 
 Braking Chopper  | 
 Frame D and above (optional)  | 
||||||||||||||
| 
 DC reactor  | 
 Frame D and above (built-in)  | 
||||||||||||||
| 
 EMI Filter  | 
 Frame D and above (optional)  | 
||||||||||||||
| 
 EMC-COP01  | 
 Optional  | 
||||||||||||||
Applications
Crane, processing machinery, printing machinery
There are currently no product reviews.