SV040iG5A-4 VFD inverter 4.0KW 380V 3 Phase NEW
- Model: SV040iG5A-4
- Shipping Weight: 3Kg
- In Stock:10
- Manufactured by: LS
SV040iG5A-4 VFD inverter 4.0KW 380V 3 Phase NEW |
Specifications 200~230V
SV IG5A-2 |
004 |
008 |
015 |
022 |
037 |
040 |
055 |
075 |
|
Max. capacity |
(HP) |
0.5 |
1 |
2 |
3 |
5 |
5.4 |
7.5 |
10 |
(kW) |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
4.0 |
5.5 |
7.5 |
|
Output rating |
Capacity (kVA) |
0.95 |
1.9 |
3.0 |
4.5 |
6.1 |
6.5 |
9.1 |
12.2 |
Rated current (A) |
2.5 |
5 |
8 |
12 |
16 |
17 |
24 |
32 |
|
Max. output frequency (Hz) |
400 |
||||||||
Max. output voltage (V) |
3 phase 200~230 |
||||||||
Input rating |
Voltage (V) |
3 phase 200~230VAC (+10%, -15%) |
|||||||
Frequency (Hz) |
50~60 |
||||||||
Cooling method |
Natural |
Forced air cooling |
|||||||
Weight |
0.76 |
0.77 |
1.12 |
1.84 |
1.89 |
1.89 |
3.66 |
3.66 |
Specifications 380~480V
SV IG5A-4 |
004 |
008 |
015 |
022 |
037 |
040 |
055 |
075 |
|
Max. capacity |
(HP) |
0.5 |
1 |
2 |
3 |
5 |
5.4 |
7.5 |
10 |
(kW) |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
4.0 |
5.5 |
7.5 |
|
Output rating |
Capacity (kVA) |
0.95 |
1.9 |
3.0 |
4.5 |
6.1 |
6.9 |
9.1 |
12.2 |
Rated current (A) |
1.25 |
2.5 |
4 |
6 |
8 |
9 |
12 |
16 |
|
Max. output frequency (Hz) |
400 |
||||||||
Max. output voltage (V) |
3 phase 380-480 |
||||||||
Input rating |
Voltage (V) |
3 phase 380-480VAC (+10%, -15%) |
|||||||
Frequency (Hz) |
50~60 |
||||||||
Cooling method |
Natural |
Forced air cooling |
|||||||
Weight |
0.76 |
0.77 |
1.12 |
1.84 |
1.89 |
1.89 |
3.66 |
3.66 |
control |
Control method |
V/F, Sensorless vector control |
|
Frequency setting resolution |
Digital command: 0.01Hz Analog command: 0.06Hz (Max. freq.: 60Hz) |
||
Frequency accuracy |
Digital command: 0.01% of Max. output frequency Analog command: 0.1% of Max. output frequency |
||
V/F pattern |
Linear, Squared, User V/F |
||
Overload capacity |
150% per 1 min. |
||
Dynamic braking |
Max. braking torque |
20% |
|
Max. Duty |
150% when using optional DB resistor |
operation |
Operation mode |
Keypad/ Terminal/ Communication option/ Remote keypad selectable |
||
Frequency setting |
Analog: 0~10V, -10~10v, 0~20mA |
|||
Digital: Keypad |
||||
Operation features |
PID, Up-down, 3-wire |
|||
input |
Multi-function terminal P1~P8 |
NPN/PNP selectable |
||
FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low, Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down, 3-wire operation, External trip A, B, PID-Inverter (V/F) operation bypass, Option-inverter (V/F) operation bypass, Analog Hold, Accel/Decel stop |
||||
output |
Open.collector terminal |
Fault output and inverter status output |
Less than DC 24V, 50mA |
|
Multi-function relay |
(N.O., N.C.) Less than AC 250V, 1A; Less than DC 30V, 1A |
|||
Analog output (AM) |
0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable |
Protective function |
Trip |
Over voltage, Under voltage, Over current, Ground fault current detection, Inverter overheat, Motor overheat, Output phase open, Overload protection, Communication error, Loss of speed command, Hardware fault, Fan trip |
Alarm |
Stall prevention, Overload |
|
Momentary power loss |
Below 15 msec.: Continuous operation (Should be within rated input voltage, rated output power.) Above 15 msec.: Auto restart enable |
|
Environ ment |
Protection degree |
IP 20, NEMA Type 1 (Optional) |
Ambient temp |
-10degree celsius~50degree celsius |
|
Storage temp |
-20degree celsius~65degree celsius |
|
Humidity |
Below 90% RH (No condensation) |
|
Altitude/Vibration |
Below 1,000m, 5.9m/sec2 (0.6G) |
|
Atmospheric pressure |
70~106 kPa |
|
Location |
Protected from corrosive gas, Combustible gas, Oil mist or dust |
There are currently no product reviews.