SV040IG5-4 VFD inverter 4.0KW 380V 3 phase NEW
- Model: SV040IG5-4
 - Shipping Weight: 4Kg
 - In Stock:10
 - Manufactured by: LS
 




                                        0 reviews                                         
                                    | SV040IG5-4 VFD inverter 4.0KW 380V 3 phase NEW | 
Specification 200~230V
| 
 Drive Type (SV_ _ _iG5-_)  | 
 004-1  | 
 008-1  | 
 015-1  | 
 004-2  | 
 008-2  | 
 015-2  | 
 022-2  | 
 037-2  | 
 040-2  | 
|
| 
 Motor Rating  | 
 [HP]  | 
 0.5  | 
 1  | 
 2  | 
 0.5  | 
 1  | 
 2  | 
 3  | 
 5  | 
 5.4  | 
| 
 [kW]  | 
 0.37  | 
 0.75  | 
 1.5  | 
 0.37  | 
 0.75  | 
 1.5  | 
 2.2  | 
 3.7  | 
 4  | 
|
| 
 
 Output ratings  | 
 Capacity[kVA]  | 
 1.1  | 
 1.9  | 
 3  | 
 1.1  | 
 1.9  | 
 3  | 
 4.5  | 
 6.1  | 
 6.5  | 
| 
 FLA[A]  | 
 3  | 
 5  | 
 8  | 
 3  | 
 5  | 
 8  | 
 12  | 
 16  | 
 17  | 
|
| 
 Frequency  | 
 0 ~ 400 Hz  | 
|||||||||
| 
 Voltage  | 
 200 ~ 230V  | 
|||||||||
| 
 Input ratings  | 
 Voltage  | 
 1 phase 200 ~ 230 V( 10%) 3 phase 200 ~ 230 V( 10%)  | 
||||||||
| 
 Frequency  | 
 50 ~ 60 Hz ( 5%) 50 ~ 60 Hz ( 5%)  | 
|||||||||
| 
 Weight[kg]  | 
 
  | 
 1.2  | 
 1.8  | 
 2.1  | 
 1.2  | 
 1.2  | 
 1.8  | 
 2.1  | 
 2.2  | 
 2.2  | 
| 
 
  | 
 Braking circuit  | 
 On board  | 
||||||||
| 
 Average braking torque  | 
 20% (with optional external braking resistor : 100%, 150%)  | 
|||||||||
| 
 Braking torque  | 
 Max.continuous braking time  | 
 15 seconds  | 
||||||||
| 
 Max. duty  | 
 0 ~ 30 % ED  | 
|||||||||
| 
 Cooling method  | 
 
  | 
 Forced air cooling Natura  | 
||||||||
| 
 Enclosure  | 
 
  | 
 IP00  | 
||||||||
Specification 380~460V
| 
 Drive Type (SV_ _ _iG5-_)  | 
 004-4  | 
 008-4  | 
 015-4  | 
 022-4  | 
 037-4  | 
 040-4  | 
|||
| 
 Motor Rating  | 
 [HP]  | 
 0.5  | 
 1  | 
 2  | 
 3  | 
 5  | 
 5.4  | 
||
| 
 [kW]  | 
 0.37  | 
 0.75  | 
 1.5  | 
 2.2  | 
 3.7  | 
 4  | 
|||
| 
 
 Output ratings  | 
 Capacity[kVA]  | 
 1.1  | 
 1.9  | 
 3  | 
 4.5  | 
 6.1  | 
 6.5  | 
||
| 
 FLA[A]  | 
 1.1  | 
 2.5  | 
 4  | 
 6  | 
 8  | 
 9  | 
|||
| 
 Input ratings  | 
 Voltage  | 
 3 phase 380 ~ 460 V( 10%)  | 
|||||||
| 
 Frequency  | 
 50 ~ 60 Hz ( 5%)  | 
||||||||
| 
 Weight[kg]  | 
 Weight [kg]  | 
 1.7  | 
 1.7  | 
 1.8  | 
 2.1  | 
 2.2  | 
 2.2  | 
||
| 
 
  | 
 Braking circuit  | 
 On board  | 
|||||||
| 
 
 Braking torque  | 
 Average braking torque  | 
 20% (with optional external braking resistor : 100%, 150%)  | 
|||||||
| 
 Max. continuous braking time  | 
 15 seconds  | 
||||||||
| 
 Max. duty  | 
 0 ~ 30 % ED  | 
||||||||
| 
 Cooling method  | 
 Forced air cooling  | 
||||||||
| 
 Enclosure  | 
 IP00  | 
||||||||
| 
 
 
 Control 
  | 
 Control method  | 
 V/F control  | 
|||||||
| 
 Frequency setting resolution  | 
 Digital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Analog reference : 0.03 Hz / 50 Hz  | 
||||||||
| 
 Frequency accuracy  | 
 Digital : 0.01% of max. output frequency Analog : 0.1% of max. output frequency  | 
||||||||
| 
 V/F ratio  | 
 Linear, Square pattern, User V/F  | 
||||||||
| 
 Overload capacity  | 
 150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time)  | 
||||||||
| 
 Torque boost  | 
 Manual torque boost (0 ~ 15 %), Auto torque boost  | 
||||||||
| 
 
 
 
 
 
 operation  | 
 Input signal  | 
 Operation method  | 
 Keypad / terminal / communication operation  | 
||||||
| 
 Frequency setting  | 
 Analog : 0 ~ 10V / 4 ~ 20 mA Digital : keypad  | 
||||||||
| 
 Start signal  | 
 Forward, Reverse  | 
||||||||
| 
 Multi-step  | 
 Up to 8 speeds can be set (use multi-function terminal)  | 
||||||||
| 
 Multi-step accel/decel time  | 
 0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal)  | 
||||||||
| 
 Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, Minimum  | 
|||||||||
| 
 Emergency stop  | 
 Interrupts the output of the drive  | 
||||||||
| 
 Jog  | 
 Jog operation  | 
||||||||
| 
 Fault reset  | 
 Resets fault when protective function is active  | 
||||||||
| 
 Output signal  | 
 Operation status  | 
 Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop,  | 
|||||||
| 
 constant speed, speed searching  | 
|||||||||
| 
 Fault output  | 
 Contact output (30A,30C,30B) - AC250V 1A, DC30V 1A  | 
||||||||
| 
 Indicator  | 
 Choose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V)  | 
||||||||
| 
 Operation function  | 
 DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention,  | 
|
| 
 auto restart, PID control  | 
||
| 
 
 Protective function  | 
 Drive trip  | 
 Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss,  | 
| 
 
  | 
 input/output mis-wiring, overload protection, communication error, loss of speed command, hardware faul  | 
|
| 
 Inverter alarm  | 
 Stall prevention, overload alarm  | 
|
| 
 Momentary power loss  | 
 Less than 15 msec : continuous operation, more than 15 msec : auto restart possible  | 
|
| 
 Display Keypad  | 
 Operation information  | 
 Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage  | 
| 
 Trip information  | 
 Indicates the fault when the protection function activates, memorizes up to 5 faults  | 
|
| 
 
 Environment  | 
 Ambient temperature  | 
 -10 °C ~ 40 °C  | 
| 
 Storage temperature  | 
 -20 °C ~ 65 °C  | 
|
| 
 Ambient humidity  | 
 90 % RH max.(Non condensing)  | 
|
| 
 Altitude . Vibration  | 
 Below 1,000 m below 5.9m/sec2(=0.6g)  | 
|
| 
 Application site  | 
 No corrosive gas, combustible gas, oil mist, or dust  | 
|
There are currently no product reviews.