SV015IC5-1F VFD inverter 1.5KW 200V Single phase NEW
- Model: SV015IC5-1F
 - Shipping Weight: 3Kg
 - In Stock:10
 - Manufactured by: LS
 




                                        0 reviews                                         
                                    | SV015IC5-1F VFD inverter 1.5KW 200V Single phase NEW | 

Specifications (200-230V class)
| 
 model  | 
 
  | 
 SV004iC5-1  | 
 SV008iC5-1  | 
 SV015iC5-1  | 
 SV022iC5-1  | 
| 
 Motor rating 
  | 
 [HP] [kW]  | 
 0.5 0.4  | 
 1 0.75  | 
 2 1.5  | 
 3 2.2  | 
| 
 Output ratings 
  | 
 Capacity[kVA] FLA[A  | 
 0.95 2.5  | 
 1.9 5  | 
 3 8  | 
 4.5 12  | 
| 
 
  | 
 Voltage  | 
 Single phase, 200 to 230V  | 
|||
| 
 
 Input ratings 
  | 
 Frequency Voltage Frequency  | 
 0 to 400Hz Single phase, 200 to 230V ( ±10%) 50 to 60Hz ( ±5% )  | 
|||
Control
| 
 Control method  | 
 V/F control, Sensorless vector control  | 
| 
 Frequency setting resolution  | 
 Digital reference : 0.01Hz Analog reference : 0.06Hz/60Hz  | 
| 
 Frequency setting accuracy  | 
 Digital : 0.01% of Maximum output frequency Analog : 0.1% of Maximum output frequency  | 
| 
 V/F ratio  | 
 Linear, Squar pattern, User V/F  | 
| 
 Overload capacity  | 
 1min. at 150%, 30sec. at 200% ( with inverse characteristic )  | 
| 
 Torque boost  | 
 Manual( 0 to 15% adjustable ), Auto  | 
Operation
| 
 Input signal 
 
 
 
 
 
 
 
 Output signal 
 
 
 
 Operation Function  | 
 oprator control Keypad / Terminal / Communications  | 
| 
 Frequency setting Analog : 0~10V/4~20mA Digital : Keypad  | 
|
| 
 Start signal Forward / Reverse  | 
|
| 
 Multi-step Setting up to 8 speeds ( use multi-function terminal )  | 
|
| 
 Multi-step accel 0.1~6000 sec. Max. 8 types available by multi-function terminal  | 
|
| 
 /decel time Selectable accel/decel patterns : Linear, U and S  | 
|
| 
 Emergency stop Interrupting the output of the drive  | 
|
| 
 Jog Jog Jog operation  | 
|
| 
 Fault reset Reset the fault when protective function is active  | 
|
| 
 Operation status & Frequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage,  | 
|
| 
 Fault output Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output ( Relay and Open collector output )  | 
|
| 
 Indicator Choose one from output frequency, current, voltage and DC voltage.(Output voltage : 0~10V ) DC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control  | 
Protection functions
| 
 Drive trip 
  | 
 Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload , External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error  | 
| 
 Drive alarm  | 
 Stall prevention, Overload alarm  | 
| 
 Momentary  | 
 Less than 15 msec : keeping operation  | 
| 
 power less  | 
 More than 15 msec : auto restart available  | 
Display keypad
| 
 Operation information  | 
 Output frequency, current and voltage, Set frequency value, Operation speed, DC voltage  | 
| 
 Trip information  | 
 Display the trip cause when the protection function activates. Recent 5 faults records stored  | 
Environment
| 
 Operating ambient temp.  | 
 -10degree Celsius ~ 4degree Celsius0  | 
| 
 Storage temperature  | 
 -20degree Celsius ~ 65  | 
| 
 Humidity  | 
 90%Rh max.(non condensing)  | 
| 
 Altitude & Vibration  | 
 1000m max, 5.9m/sec2(0.6g) max.  | 
| 
 Atmosphere  | 
 No corrosive gas, flammable gas, oil mist or dust  | 
| 
 Pressure  | 
 70~106k Pa  | 
Dimension

There are currently no product reviews.