SV015IC5-1 VFD inverter 1.5KW Single phase 200V NEW
- Model: SV015IC5-1
- Shipping Weight: 3Kg
- In Stock:10
- Manufactured by: LS
SV015IC5-1 VFD inverter 1.5KW Single phase 200V NEW |
Specifications (200-230V class)
model |
|
SV004iC5-1 |
SV008iC5-1 |
SV015iC5-1 |
SV022iC5-1 |
Motor rating
|
[HP] [kW] |
0.5 0.4 |
1 0.75 |
2 1.5 |
3 2.2 |
Output ratings
|
Capacity[kVA] FLA[A |
0.95 2.5 |
1.9 5 |
3 8 |
4.5 12 |
|
Voltage |
Single phase, 200 to 230V |
|||
Input ratings
|
Frequency Voltage Frequency |
0 to 400Hz Single phase, 200 to 230V ( ±10%) 50 to 60Hz ( ±5% ) |
Control
Control method |
V/F control, Sensorless vector control |
Frequency setting resolution |
Digital reference : 0.01Hz Analog reference : 0.06Hz/60Hz |
Frequency setting accuracy |
Digital : 0.01% of Maximum output frequency Analog : 0.1% of Maximum output frequency |
V/F ratio |
Linear, Squar pattern, User V/F |
Overload capacity |
1min. at 150%, 30sec. at 200% ( with inverse characteristic ) |
Torque boost |
Manual( 0 to 15% adjustable ), Auto |
Operation
Input signal
Output signal
Operation Function |
oprator control Keypad / Terminal / Communications |
Frequency setting Analog : 0~10V/4~20mA Digital : Keypad |
|
Start signal Forward / Reverse |
|
Multi-step Setting up to 8 speeds ( use multi-function terminal ) |
|
Multi-step accel 0.1~6000 sec. Max. 8 types available by multi-function terminal |
|
/decel time Selectable accel/decel patterns : Linear, U and S |
|
Emergency stop Interrupting the output of the drive |
|
Jog Jog Jog operation |
|
Fault reset Reset the fault when protective function is active |
|
Operation status & Frequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage, |
|
Fault output Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output ( Relay and Open collector output ) |
|
Indicator Choose one from output frequency, current, voltage and DC voltage.(Output voltage : 0~10V ) DC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control |
Protection functions
Drive trip
|
Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload , External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error |
Drive alarm |
Stall prevention, Overload alarm |
Momentary |
Less than 15 msec : keeping operation |
power less |
More than 15 msec : auto restart available |
Display keypad
Operation information |
Output frequency, current and voltage, Set frequency value, Operation speed, DC voltage |
Trip information |
Display the trip cause when the protection function activates. Recent 5 faults records stored |
Environment
Operating ambient temp. |
-10degree Celsius ~ 4degree Celsius0 |
Storage temperature |
-20degree Celsius ~ 65 |
Humidity |
90%Rh max.(non condensing) |
Altitude & Vibration |
1000m max, 5.9m/sec2(0.6g) max. |
Atmosphere |
No corrosive gas, flammable gas, oil mist or dust |
Pressure |
70~106k Pa |
Dimension
There are currently no product reviews.