SMH80S-0100-30ABK-3LKH+ED430-0100-PA-K-000 AC220V 1KW 6.3A 3.18NM 3Krpm 80mm Brake AC Servo Motor Drive kits with 3M cable
- Shipping Weight: 9Kg
- In Stock:10
- Manufactured by: Kinco
Motor + Drive: SMH80S-0100-30ABK-3LKH+ED430-0100-PA-K-000
1 Motor Specifications
Motor series |
Small inertia, flange size 80mm |
|
Model |
SMH80S-0100-30ABK-3LKH |
|
DC link voltage UDC |
300 |
|
Continuous |
Rated power PN (W) |
1000 |
Rated torque TN (Nm) |
3.18 |
|
Rated speed nN (rpm) |
3000 |
|
Rated current IN (A) |
6.3 |
|
Maximum torque Tm (Nm) |
9.48 |
|
Maximum current Im (A) |
18.9 |
|
Standstill torque TS (Nm) |
3.3 |
|
Standstill current IS (A) |
6.93 |
|
Resistance line-line RL (Ω) |
0.86 |
|
Inductance line-line LL (mH) |
4.5 |
|
Electrical time constant τe (ms) |
5.23 |
|
Mechanical time constant τm (ms) |
0.89 |
|
Reverse voltage constant Ke (V/krpm) |
34 |
|
Torque constant Kt (Nm/A) |
0.562 |
|
Rotor moment of inertia Jm (Kg·cm² ) |
1.9 |
|
Pole pair number |
3 |
|
Maximum voltage rising du/dt (KV/μs) |
8 |
|
Insulation class |
F |
|
Maximum radial force F (N) |
335 |
|
Maximum axial force F (N) |
167.5 |
|
Weight G(Kg) |
4.6(with brake) |
|
Length of motor L(mm) |
217±1.5(with brake) |
|
Position feedback device |
Incremental encoder 2500ppr |
|
Cooling method |
Totally enclosed, non-ventilated |
|
Protection level |
IP65 for body, shaft sealing IP54 |
|
Environmental |
Temperature |
-20centigrade degree~40centigrade degree |
Humidity |
Below 90% RH (No condensing) |
|
Ambient enviroment |
Away from active gas, combustible gas, oil drops and dust |
|
Altitude |
Maximum altitude 4000m, Rated power at 1000m or below, Above 1000m: Decreasing 1.5% per 100m rise |
2 Drive Specifications
Model |
ED430 |
ED430-0100-PA-K-000 |
|
Main Supply Voltage |
Single-Phase AC220V±15% |
Rated Power Frequency |
50Hz~60Hz |
Control Power Supply |
DC24±10% , 2A |
Digital Signal Input |
DC24±10%, 10mA |
Digital Signal Output |
DC24±10%, 0.5A |
Analog Signal Input |
-10V~+10V |
Rated Output Power(KW) |
1 |
Energy-Consumed Braking |
If the system generates an over-voltage alarm when it starts or stops sharply, add an external braking resistor to absorb the feedback energy of the motor, the minimum resistance for ED430 Series is 27W |
Energy-Consumed Braking Voltage |
DC385±5V |
Over-Voltage Alarm Voltage |
DC400±5V |
Under-Voltage Alarm Voltage |
DC210±5V |
Dimensions mm (H×W×D) |
265X165X97 |
Weight |
3Kg |
Operating Temperature |
0~40centigrade degree |
Storage Temperature |
-10~70centigrade degree |
Humidity |
5~85% |
Contamination Level |
2 |
Protection Level |
IP20 |
Installation Environment |
Installed in a Dust-Free, Dry, and Lockable Environment (in a Electrical Cabinet, for Example) |
Installation Mode |
Vertical Installation |
Installation Altitude |
No Power Limit Under 1000m |
Pressure |
86~106Kpa |
Internal Programmable |
An Internal Space of 16.5 KB is Provided for 256 Sequences, Which can Save a Controller on Some Occasions |
External I/O |
3 External Digital Outputs (24V,0.5A),the Target Position to Output or Alarm Output Function can be Implemented by Internal Programming |
8 External Digital Inputs, Supporting Internal Sequence Calling Via the Input Interface and Positioning Function |
|
(Input Delay: About 1 ms; Input Current: About 4 mA) |
|
Analog Input |
One Differential Analog Input, Implementing Control Over Motor Speed and Position by Analog Input; Input Voltage Range ± 10V, Input Delay: About 0.1 ms |
Analog Output |
Two Independent Analog Outputs, Capable of Monitoring the Change of Internal Object |
Comparator |
Four Internal Comparators, With the Comparison Results to be Used to Trigger Program Sequences |
Timer |
Supporting the Function of Triggering Sequences by Timer or Events |
Counter |
Four Groups of Internal Counters, Which can be Set to Trigger Sequences |
Calculator |
An Internal Calculator can be Used for Data Duplication, Addition, Subtraction, Multiplication, and Division, and Logic Operation |
Internal Oscilloscope |
The ECO2WIN Software Enables a User to Monitor Operation Parameters Such as Speed, Position and Current on a PC |
Encoder Signal Output Function |
In a Master/Slave Control Mode, the Motor Encoder Signal or Master Encoder Signal can be the Input for the Slave Signal Encoder, With a Maximum Output Frequency of 2 MHz |
Master Encoder Signal Input Function |
Programmable to be Pulse/Direction Signal Control, CW/CCWW Control, Electronic Gear or electronic cam control (5V signal), with a maximum input frequency of 2 MHz |
Feedback Signal |
Incremental A, B, Z , /A, /B, /Z Signal |
RS232 |
9.6K Baud Rate, Supporting a Maximum of 15 Sites, and Supporting Direct Communication with a PC with the ECO2WIN Software, or Direct Communication with an eView Touch Screen or Text |
RS485 |
38.4K Baud Rate, Supporting a Maximum of 15 Sites, and Communication Cables with a Length up to 400M |
CAN BUS |
Maximum Baud Rate of 1M, and Supporting a Maximum of 127 Sites |
PROFIBUS DP |
Maximum Baud Rate of 12M, and Supporting a Maximum of 127 Sites |
There are currently no product reviews.