                                    Motor + Drive: SMH80S-0075-30AAK-3LKH+ED430-0075-LA-K-000
1 Motor Specifications
| Motor series | Small inertia, flange size 80mm | |
| Model | SMH80S-0075-30AAK-3LKH | |
| DC link voltage UDC | 300 | |
| Continuous | Rated power PN (W) | 750 | 
| Rated torque TN (Nm) | 2.39 | |
| Rated speed nN (rpm) | 3000 | |
| Rated current IN (A) | 3.9 | |
| Maximum torque Tm (Nm) | 7.17 | |
| Maximum current Im (A) | 11.7 | |
| Standstill torque TS (Nm) | 2.63 | |
| Standstill current IS (A) | 4.4 | |
| Resistance line-line RL (Ω) | 1.4 | |
| Inductance line-line LL (mH) | 7.5 | |
| Electrical time constant τe (ms) | 5.35 | |
| Mechanical time constant τm (ms) | 0.75 | |
| Reverse voltage constant Ke (V/krpm) | 40 | |
| Torque constant Kt (Nm/A) | 0.662 | |
| Rotor moment of inertia Jm (Kg·cm² ) | 1.36 | |
| Pole pair number | 3 | |
| Maximum voltage rising du/dt (KV/μs) | 8 | |
| Insulation class | F | |
| Maximum radial force F (N) | 335 | |
| Maximum axial force F (N) | 167.5 | |
| Weight G(Kg) | 3.3 | |
| Length of motor L(mm) | 147 | |
| Position feedback device | Incremental encoder 2500ppr | |
| Cooling method | Totally enclosed, non-ventilated | |
| Protection level | IP65 for body, shaft sealing IP54 | |
| Environmental  | Temperature | -20centigrade degree~40centigrade degree | 
| Humidity | Below 90% RH (No condensing) | |
| Ambient enviroment | Away from active gas, combustible gas, oil drops and dust | |
| Altitude | Maximum altitude 4000m, Rated power at 1000m or below, Above 1000m: Decreasing 1.5% per 100m rise | |
2 Drive Specifications
| Model | ED430 | 
| ED430-0075-LA-K-000 | |
| Main Supply Voltage | Single-Phase AC220V±15% | 
| Rated Power Frequency | 50Hz~60Hz | 
| Control Power Supply | DC24±10% , 2A | 
| Digital Signal Input | DC24±10%, 10mA | 
| Digital Signal Output | DC24±10%, 0.5A | 
| Analog Signal Input | -10V~+10V | 
| Rated Output Power(KW) | 0.75 | 
| Energy-Consumed Braking | If the system generates an over-voltage alarm when it starts or stops sharply, add an external braking resistor to absorb the feedback energy of the motor, the minimum resistance for ED430 Series is 27W | 
| Energy-Consumed Braking Voltage | DC385±5V | 
| Over-Voltage Alarm Voltage | DC400±5V | 
| Under-Voltage Alarm Voltage | DC210±5V | 
| Dimensions mm (H×W×D) | 265X165X62 | 
| Weight | 1.9Kg | 
| Operating Temperature | 0~40centigrade degree | 
| Storage Temperature | -10~70centigrade degree | 
| Humidity | 5~85% | 
| Contamination Level | 2 | 
| Protection Level | IP20 | 
| Installation Environment | Installed in a Dust-Free, Dry, and Lockable Environment (in a Electrical Cabinet, for Example) | 
| Installation Mode | Vertical Installation | 
| Installation Altitude | No Power Limit Under 1000m | 
| Pressure | 86~106Kpa | 
| Internal Programmable | An Internal Space of 16.5 KB is Provided for 256 Sequences, Which can Save a Controller on Some Occasions | 
| External I/O | 3 External Digital Outputs (24V,0.5A),the Target Position to Output or Alarm Output Function can be Implemented by Internal Programming | 
| 8 External Digital Inputs, Supporting Internal Sequence Calling Via the Input Interface and Positioning Function | |
| (Input Delay: About 1 ms; Input Current: About 4 mA) | |
| Analog Input | One Differential Analog Input, Implementing Control Over Motor Speed and Position by Analog Input; Input Voltage Range ± 10V, Input Delay: About 0.1 ms | 
| Analog Output | Two Independent Analog Outputs, Capable of Monitoring the Change of Internal Object | 
| Comparator | Four Internal Comparators, With the Comparison Results to be Used to Trigger Program Sequences | 
| Timer | Supporting the Function of Triggering Sequences by Timer or Events | 
| Counter | Four Groups of Internal Counters, Which can be Set to Trigger Sequences | 
| Calculator | An Internal Calculator can be Used for Data Duplication, Addition, Subtraction, Multiplication, and Division, and Logic Operation | 
| Internal Oscilloscope | The ECO2WIN Software Enables a User to Monitor Operation Parameters Such as Speed, Position and Current on a PC | 
| Encoder Signal Output Function | In a Master/Slave Control Mode, the Motor Encoder Signal or Master Encoder Signal can be the Input for the Slave Signal Encoder, With a Maximum Output Frequency of 2 MHz | 
| Master Encoder Signal Input Function | Programmable to be Pulse/Direction Signal Control, CW/CCWW Control, Electronic Gear or electronic cam control (5V signal), with a maximum input frequency of 2 MHz | 
| Feedback Signal | Incremental A, B, Z , /A, /B, /Z Signal | 
| RS232 | 9.6K Baud Rate, Supporting a Maximum of 15 Sites, and Supporting Direct Communication with a PC with the ECO2WIN Software, or Direct Communication with an eView Touch Screen or Text | 
| RS485 | 38.4K Baud Rate, Supporting a Maximum of 15 Sites, and Communication Cables with a Length up to 400M | 
| CAN BUS | Maximum Baud Rate of 1M, and Supporting a Maximum of 127 Sites | 
| PROFIBUS DP | Maximum Baud Rate of 12M, and Supporting a Maximum of 127 Sites | 
There are currently no product reviews.

 
            
            