Product Specifications
Single / Three phase, 200-240V model
N310-xxxx-XXX |
20P5 |
2001 |
2002 |
2003 |
Horsepower(HP) |
0.5 |
1 |
2 |
3 |
Max Applicable Motor Output (KW) |
0.4 |
0.75 |
1.5 |
2.2 |
Rated Output Current(A) |
3.1 |
4.5 |
7.5 |
10.5 |
Rated Capacity(KVA) |
1.2 |
1.7 |
2.9 |
4.0 |
Max. Input Voltage |
Single/Three Phase: 200~240V +10% -15%, 50/60HZ,+- 5% |
|||
Max. Output Voltage |
Three Phase: 200~240V |
|||
Input Current(A) |
8.5/4.5 |
12/6.5 |
16/11 |
23.9/12.5 |
Net Weight (KG) |
1.4 |
1.4 |
2.5 |
4.0 |
Allowable momentary power loss time (second) |
1.0 |
1.0 |
2.0 |
2.0 |
Three phase, 380 – 480V model
N310-xxxx-XXX |
4001 |
4002 |
4003 |
4005 |
4008 |
4010 |
4015 |
Horsepower(HP) |
1 |
2 |
3 |
5 |
7.5 |
10 |
15 |
Max Applicable Motor Output (KW) |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
Rated Output Current(A) |
2.3 |
3.8 |
5.2 |
8.8 |
13.0 |
17.5 |
25 |
Rated Capacity(KVA) |
1.7 |
2.9 |
4.0 |
6.7 |
9.9 |
13.3 |
19.1 |
Max. Input Voltage |
Three phase 380~480V +10%-15% 50/60HZ+-5% |
||||||
Max. Output Voltage |
Three Phase 380V~480V |
||||||
Input Current(A) |
4.2 |
5.6 |
7.3 |
11.6 |
17 |
23 |
31 |
Net Weight (KG) |
2.4 |
2.5 |
3.8 |
4.0 |
4.0 |
7.0 |
7.0 |
Allowable momentary power loss time (second) |
1.0 |
1.0 |
2.0 |
2.0 |
2.0 |
2.0 |
2.0 |
General Specifications
Item |
N310 TYPE |
||
Control Mode |
V/F or Current Vector Control |
||
Frequency Control |
Range |
0.01~400.00 Hz |
|
Start control torque |
150%/1Hz ( Vector) |
||
Speed control range |
1:100 ( Vector) |
||
Speed Control Precision |
+-0.5% (Vector) |
||
Setting resolution |
Digital: 0.01Hz, Analog: 0.06Hz/ 60Hz(10bits) |
||
Keypad setting |
Set directly with”up””down” keys or the VR on the keypad |
||
Display Function |
Five digital LED and status indicator; display frequency/ line speed/ DC voltage/ Output voltage/ Current/ Rotation direction/ Inverter parameter/ Fault Log/ Program Version / Heat sink temperature/PID feed back |
||
External signal setting |
1. External potentiometer0-10V/ 0-20mA 2. Provides up/down controls, speed control or automatic procedure control with multifunctional contacts on the terminal block (TM2) |
||
Frequency Limit Function |
Upper/lower frequency limits and three programmable skip frequencies |
||
Carrier frequency |
1~ 15 kHz |
||
V/F pattern |
18 fixed patterns, 1programable curve |
||
Acc/Dec control |
Two-stage Acc/Dec time (0.1 – 3,600 seconds) and four-stage S curves (refer to descriptions on 10-07..) |
||
Multifunction analog output |
5 functions (refer to description on 2-12)
|
||
Multifunction input
|
23 functions (refer to description on 01-00~01-05) |
||
Multifunction output |
14functions (refer to description on 01-09~01-10) |
||
Other Functions |
Momentary Power Loss Restart, Speed Search, Overload Detection, 16 preset speeds. Acc/Dec Switch (2 Stages), S Curves, 3-wire Control, PID control, torque boost, Slip Compensation, Frequency Upper/ Lower Limit, Auto energy saving, Modbus slave and PC/PDA Link, Auto Restart, Encoder input. |
||
Communication Control |
1. Control by RS232 or RS485 2. One to one or one to many (RS485 ONLY) control. 3. BAUD RATE/STOP BIT/PARITY/bit can be set |
||
Braking Torque |
About 20%, the model below 20HP with built-in braking transistor and the specified external braking resistors can provide 100% |
||
Operation temperature |
14-1200F(-10 ~ 500C) |
||
Storage temperature |
4-1400F(-20 ~ 600C) |
||
Humidity |
0 -95% Relative Humidity(Non-condense) |
||
Vibration |
1G (9.8m/ S2 ) |
||
Enclosure |
IP20 |
||
Protective Functions |
Overload protection |
The relays to protect the motor (the curve can be set) and the inverter (150 % / 1min) |
|
Over Voltage |
200V class: DC Voltage>410V 400Vclass: DC Voltage>820V |
||
Under Voltage |
200V class: DC Voltage<190V 400Vclass: DC Voltage<380V |
||
Momentary Power Loss Restart |
Restart can be initiated with spin start after momentary power loss in Max 2 sec |
||
Stall Prevention |
Stall prevention for Acceleration/ Deceleration/ Operation. |
||
Short-circuit output terminal |
Electronic Circuit Protection |
||
Grounding Fault |
Electronic Circuit Protection |
||
Other Function |
Protection for overheating of heat sink, over torque detection, error contact control, reverse prohibit, prohibit for direct start after power up and error recovery, parameter lock up. |
||
Wiring