N310-2002-H TECO 1/3Phase 200V 7.5A output 1.5KW 2HP Inverter NEW
- Model: N310-2002-H
- Shipping Weight: 3.5Kg
- In Stock:20




 0 reviews
                                        0 reviews                                         
                                    


Product Specifications
Single / Three phase, 200-240V model
| N310-xxxx-XXX | 20P5 | 2001 | 2002 | 2003 | 
| Horsepower(HP) | 0.5 | 1 | 2 | 3 | 
| Max Applicable Motor Output (KW) | 0.4 | 0.75 | 1.5 | 2.2 | 
| Rated Output Current(A) | 3.1 | 4.5 | 7.5 | 10.5 | 
| Rated Capacity(KVA) | 1.2 | 1.7 | 2.9 | 4.0 | 
| Max. Input Voltage | Single/Three Phase: 200~240V +10% -15%, 50/60HZ,+- 5% | |||
| Max. Output Voltage | Three Phase: 200~240V | |||
| Input Current(A) | 8.5/4.5 | 12/6.5 | 16/11 | 23.9/12.5 | 
| Net Weight (KG) | 1.4 | 1.4 | 2.5 | 4.0 | 
| Allowable momentary power loss time (second) | 1.0 | 1.0 | 2.0 | 2.0 | 
Three phase, 380 – 480V model
| N310-xxxx-XXX | 4001 | 4002 | 4003 | 4005 | 4008 | 4010 | 4015 | 
| Horsepower(HP) | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 
| Max Applicable Motor Output (KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 
| Rated Output Current(A) | 2.3 | 3.8 | 5.2 | 8.8 | 13.0 | 17.5 | 25 | 
| Rated Capacity(KVA) | 1.7 | 2.9 | 4.0 | 6.7 | 9.9 | 13.3 | 19.1 | 
| Max. Input Voltage | Three phase 380~480V +10%-15% 50/60HZ+-5% | ||||||
| Max. Output Voltage | Three Phase 380V~480V | ||||||
| Input Current(A) | 4.2 | 5.6 | 7.3 | 11.6 | 17 | 23 | 31 | 
| Net Weight (KG) | 2.4 | 2.5 | 3.8 | 4.0 | 4.0 | 7.0 | 7.0 | 
| Allowable momentary power loss time (second) | 1.0 | 1.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 
General Specifications
| Item | N310 TYPE | ||
| Control Mode | V/F or Current Vector Control | ||
| Frequency Control | Range | 0.01~400.00 Hz | |
| Start control torque | 150%/1Hz ( Vector) | ||
| Speed control range | 1:100 ( Vector) | ||
| Speed Control Precision | +-0.5% (Vector) | ||
| Setting resolution | Digital: 0.01Hz, Analog: 0.06Hz/ 60Hz(10bits) | ||
| Keypad setting | Set directly with”up””down” keys or the VR on the keypad | ||
| Display Function | Five digital LED and status indicator; display frequency/ line speed/ DC voltage/ Output voltage/ Current/ Rotation direction/ Inverter parameter/ Fault Log/ Program Version / Heat sink temperature/PID feed back | ||
| External signal setting | 1. External potentiometer0-10V/ 0-20mA 2. Provides up/down controls, speed control or automatic procedure control with multifunctional contacts on the terminal block (TM2) | ||
| Frequency Limit Function | Upper/lower frequency limits and three programmable skip frequencies | ||
| Carrier frequency | 1~ 15 kHz | ||
| V/F pattern | 18 fixed patterns, 1programable curve | ||
| Acc/Dec control | Two-stage Acc/Dec time (0.1 – 3,600 seconds) and four-stage S curves (refer to descriptions on 10-07..) | ||
| Multifunction analog output | 5 functions (refer to description on 2-12) 
 | ||
| Multifunction input 
 | 23 functions (refer to description on 01-00~01-05) | ||
| Multifunction output | 14functions (refer to description on 01-09~01-10) | ||
| Other Functions | Momentary Power Loss Restart, Speed Search, Overload Detection, 16 preset speeds. Acc/Dec Switch (2 Stages), S Curves, 3-wire Control, PID control, torque boost, Slip Compensation, Frequency Upper/ Lower Limit, Auto energy saving, Modbus slave and PC/PDA Link, Auto Restart, Encoder input. | ||
| Communication Control | 1. Control by RS232 or RS485 2. One to one or one to many (RS485 ONLY) control. 3. BAUD RATE/STOP BIT/PARITY/bit can be set | ||
| Braking Torque | About 20%, the model below 20HP with built-in braking transistor and the specified external braking resistors can provide 100% | ||
| Operation temperature | 14-1200F(-10 ~ 500C) | ||
| Storage temperature | 4-1400F(-20 ~ 600C) | ||
| Humidity | 0 -95% Relative Humidity(Non-condense) | ||
| Vibration | 1G (9.8m/ S2 ) | ||
| Enclosure | IP20 | ||
| Protective Functions | Overload protection | The relays to protect the motor (the curve can be set) and the inverter (150 % / 1min) | |
| Over Voltage | 200V class: DC Voltage>410V 400Vclass: DC Voltage>820V | ||
| Under Voltage | 200V class: DC Voltage<190V 400Vclass: DC Voltage<380V | ||
| Momentary Power Loss Restart | Restart can be initiated with spin start after momentary power loss in Max 2 sec | ||
| Stall Prevention | Stall prevention for Acceleration/ Deceleration/ Operation. | ||
| Short-circuit output terminal | Electronic Circuit Protection | ||
| Grounding Fault | Electronic Circuit Protection | ||
| Other Function | Protection for overheating of heat sink, over torque detection, error contact control, reverse prohibit, prohibit for direct start after power up and error recovery, parameter lock up. | ||
Wiring

There are currently no product reviews.

 
            
            