N2-420-H3 TECO 3 phase 400V 32A output 15KW 20HP Inverter VFD frequency AC drive NEW
- Model: N2-420-H3
 - Shipping Weight: 14Kg
 - In Stock:20
 




                                        0 reviews                                         
                                    

Product Specifications
1/ 3 Phase 200-240 Volts
| 
 N2-xxx—xxx  | 
 2P5  | 
 201  | 
 202  | 
 203  | 
 205  | 
 208  | 
 210  | 
 215  | 
 220  | 
 230  | 
| 
 Horse Power  | 
 1/2 
  | 
 1  | 
 2  | 
 3  | 
 5  | 
 7.5  | 
 10  | 
 15  | 
 20  | 
 30  | 
| 
 Rated Motor KW  | 
 0.4  | 
 0.75  | 
 1.5  | 
 2.2  | 
 3.7  | 
 5.5  | 
 7.5  | 
 11  | 
 15  | 
 22  | 
| 
 Rated Current (A)  | 
 3.1  | 
 4.5  | 
 7.5  | 
 10.5  | 
 17.5  | 
 26  | 
 35  | 
 49  | 
 64  | 
 87  | 
| 
 Output (KVA)  | 
 1.2  | 
 1.7  | 
 2.9  | 
 4.0  | 
 6.7  | 
 9.9  | 
 13.3  | 
 18.7  | 
 24.4  | 
 33.2  | 
| 
 Input Voltage Max.  | 
 (1 / 3 Phase) (200~240 Volts +-10%) (50/60Hz +-5%) (5 h.p. & above 3 Phase Only)  | 
|||||||||
| 
 Output Voltage Max.  | 
 3 Phase 200 ~ 240 (proportional to input voltage)  | 
|||||||||
| 
 IP20 Weight (Kg)  | 
 1.4  | 
 1.4  | 
 2.5  | 
 4.0  | 
 4.0  | 
 6.8  | 
 7.1  | 
 12.3  | 
 12.5  | 
 13.8  | 
| 
 Power Loss Ride Through (s)  | 
 1  | 
 1  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
3 Phase 380 ~ 480 Volts
| 
 N2-xxx—xxx  | 
 401  | 
 402  | 
 403  | 
 405  | 
 408  | 
 410  | 
 415  | 
 420  | 
 430  | 
| 
 Horse Power  | 
 1 
  | 
 2  | 
 3  | 
 5  | 
 7.5  | 
 10  | 
 15  | 
 20  | 
 30  | 
| 
 Rated Motor KW  | 
 0.75  | 
 1.5  | 
 2.2  | 
 3.7  | 
 5.5  | 
 7.5  | 
 11  | 
 15  | 
 22  | 
| 
 Rated Current (A)  | 
 2.3  | 
 3.8  | 
 5.2  | 
 8.8  | 
 13  | 
 17.5  | 
 25  | 
 32  | 
 48  | 
| 
 Output (KVA)  | 
 1.7  | 
 2.9  | 
 4.0  | 
 6.7  | 
 9.9  | 
 13.3  | 
 19.1  | 
 24.4  | 
 36.6  | 
| 
 Input Voltage Max  | 
 ( 3 Phase 380 ~ 480 Volts +- 10%) (50/60Hz +- 5%)  | 
||||||||
| 
 Output Voltage Max.  | 
 3 Phase 380 ~ 480 Volts (proportional to input voltage)  | 
||||||||
| 
 IP20 Weight (Kg)  | 
 2.4  | 
 2.5  | 
 3.8  | 
 4.0  | 
 7.0  | 
 7.3  | 
 12.3  | 
 12.5  | 
 13.5  | 
| 
 Power Loss Ride Through (s)  | 
 1  | 
 1  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
 2  | 
Functional Specification
| 
 Control Characteristics  | 
 Carrier frequency  | 
 1 - 12 K  | 
|
| 
 Frequency Control Range  | 
 0.1 – 400 Hz  | 
||
| 
 Frequency Accuracy  | 
 Digital: 0.01% (-10 ~ 40 °C); Analog: 0.4% (25+-10 °C)  | 
||
| 
 Frequency Resolution  | 
 0.01 Hz with computer or PLC control, 0.1 Hz with keypad control when freq. above 100 Hz  | 
||
| 
 Frequency Setting Signal  | 
 (0-5VDC) (0-10VDC) (4-20mA) (0-20mA)  | 
||
| 
 Accel / Decel Time  | 
 0.1-3600 SEC with (2) S-curves  | 
||
| 
 Braking Torque  | 
 About 20% (built-in Braking transistor)  | 
||
| 
 V/F Pattern  | 
 18 patterns, one curve programmable  | 
||
| 
 Protection Function  | 
 Instantaneous Over Current  | 
 Approx. 200% rated current  | 
|
| 
 Overload  | 
 T-verter: 150% / 1 minute  | 
||
| 
 Motor Overload Protection  | 
 Electronic thermal overload relay  | 
||
| 
 Over voltage  | 
 200V series: (DC bus voltage exceeds 427V) 400v series: (DC bus voltage exceeds 854V)  | 
||
| 
 Under voltage  | 
 200V series: (DC bus voltage drops < 200V) 400v series: (DC bus voltage drops < 400V)  | 
||
| 
 Momentary Power Loss  | 
 0~2 seconds: The T-verter can be restarted using the speed search feature  | 
||
| 
 Heat Sink Fin Overheat  | 
 Protected by thermister  | 
||
| 
 Ground Fault  | 
 Electronic circuit protection  | 
||
| 
 Operation Conditions  | 
 Input Signal  | 
 Operation signals  | 
 Forward/Reverse operation, by keypad or hardwire contact, multiple individual commands  | 
| 
 Reset  | 
 Released protection while the protective function is operating  | 
||
| 
 Multifunction Input  | 
 Refer to function illustration in Fn_56  | 
||
| 
 Output Signal  | 
 Multifunction Output  | 
 Refer to function illustration in Fn_61  | 
|
| 
 Fault output  | 
 250VAC 1A, 30VDC 1A or less  | 
||
| 
 Built-in Function  | 
 Frequency reference bias/gain; up/lower limit; manual torque boost; frequency meter calibrating gain; auto restart attempt; skip frequency; S-curve ACCEL/DECEL; Carrier frequency adjust.(1-12KHz) Communication link function  | 
||
| 
 Digital operator monitor  | 
 Frequency command, output frequency, speed, output current, output voltage, P-N bus voltage, rotating direction  | 
||
| 
 Analog Output Monitor  | 
 Analog output (0-10V), possible to select output frequency & setting freq. & output voltage & P-N bus voltage  | 
||
| 
 Environmental  | 
 Location  | 
 Indoor (protected from corrosive gas and dust)  | 
|
| 
 Ambient Temperature  | 
 -10 degrees ~ 40 degrees © 50 degrees with cover removed  | 
||
| 
 Humidity  | 
 0-95%(non condensing)  | 
||
| 
 Vibration  | 
 0.5G  | 
||
| 
 Enclosure  | 
 IP20 / IP65 (NEMA4)  | 
||
| 
 EMC  | 
 EN50081-1, EN50082-2 (with optional filter)  | 
||
| 
 LVD  | 
 EN50178  | 
||
| 
 UL  | 
 UL 508C  | 
||
N2-205 and above capacity are not CE complied
Wiring

There are currently no product reviews.