SV185iG5A-2 VFD inverter 18.5KW 3 Phase NEW
- Model: SV185iG5A-2
 - Shipping Weight: 15Kg
 - In Stock:10
 - Manufactured by: LS
 




                                        0 reviews                                         
                                    | SV185iG5A-2 VFD inverter 18.5KW 3 Phase NEW | 
Specifications
| 
 
 
 
 
 control  | 
 Control method  | 
 V/F, Sensorless vector control  | 
|
| 
 Frequency setting resolution  | 
 Digital command: 0.01Hz Analog command: 0.06Hz (Max. freq.: 60Hz)  | 
||
| 
 Frequency accuracy  | 
 Digital command: 0.01% of Max. output frequency Analog command: 0.1% of Max. output frequency  | 
||
| 
 V/F pattern  | 
 Linear, Squared, User V/F  | 
||
| 
 Overload capacity  | 
 150% per 1 min.  | 
||
| 
 Dynamic braking  | 
 Max. braking torque  | 
 20%  | 
|
| 
 Max. Duty  | 
 150% when using optional DB resistor  | 
||
| 
 
 
 
 
 
 operation  | 
 Operation mode  | 
 Keypad/ Terminal/ Communication option/ Remote keypad selectable  | 
||
| 
 Frequency setting  | 
 Analog: 0~10V, -10~10v, 0~20mA  | 
|||
| 
 Digital: Keypad  | 
||||
| 
 Operation features  | 
 PID, Up-down, 3-wire  | 
|||
| 
 input  | 
 Multi-function terminal P1~P8  | 
 NPN/PNP selectable  | 
||
| 
 FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low, Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down, 3-wire operation, External trip A, B, PID-Inverter (V/F) operation bypass, Option-inverter (V/F) operation bypass, Analog Hold, Accel/Decel stop  | 
||||
| 
 output  | 
 Open.collector terminal  | 
 Fault output and inverter status output  | 
 Less than DC 24V, 50mA  | 
|
| 
 Multi-function relay  | 
 (N.O., N.C.) Less than AC 250V, 1A; Less than DC 30V, 1A  | 
|||
| 
 Analog output (AM)  | 
 0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable  | 
|||
| 
 Protective function  | 
 Trip  | 
 Over voltage, Under voltage, Over current, Ground fault current detection, Inverter overheat, Motor overheat, Output phase open, Overload protection, Communication error, Loss of speed command, Hardware fault, Fan trip  | 
| 
 Alarm  | 
 Stall prevention, Overload  | 
|
| 
 Momentary power loss  | 
 Below 15 msec.: Continuous operation (Should be within rated input voltage, rated output power.) Above 15 msec.: Auto restart enable  | 
|
| 
 Environ ment  | 
 Protection degree  | 
 IP 20, NEMA Type 1 (Optional)  | 
| 
 Ambient temp  | 
 -10degree celsius~50degree celsius  | 
|
| 
 Storage temp  | 
 -20degree celsius~65degree celsius  | 
|
| 
 Humidity  | 
 Below 90% RH (No condensation)  | 
|
| 
 Altitude/Vibration  | 
 Below 1,000m, 5.9m/sec2 (0.6G)  | 
|
| 
 Atmospheric pressure  | 
 70~106 kPa  | 
|
| 
 Location  | 
 Protected from corrosive gas, Combustible gas, Oil mist or dust  | 
There are currently no product reviews.