GD100-7R5G-4 3-phase 380V 7.5KW 25A Input INVT Inverter VFD frequency AC drive NEW
- Model: GD100-7R5G-4
- Shipping Weight: 9Kg
- In Stock:20
Brief Introduction
Goodrive 100 series inverters are compact high-performance type products in the universal market. Applying V/F and sensorless vector control mode, separately air-duct design, book structure, brand-new design platform, and built-in C3 input filter, the products enhance its performance to meet the complicated and rugged environment.
Product Features
1. More Accurate Motor Autotuning
2. Excellent Performance
3. Separate Air-duct
4. C3 input filter (standard configuration) and C2 filter (optional)
Power Ratings
Model NO. |
Output Power (kw) |
Input Current (A) |
Output Current (A) |
Carrier Frequency (kHz) |
GD100-0R7G-4 |
0.75 |
3.4 |
2.5 |
2~15(8) |
GD100-1R5G-4 |
1.5 |
5.0 |
3.7 |
2~15(8) |
GD100-2R2G-4 |
2.2 |
5.8 |
5 |
2~15(8) |
GD100-004G-4 |
4 |
13.5 |
9.5 |
2~15(8) |
GD100-5R5G-4 |
5.5 |
19.5 |
14 |
2~15(8) |
GD100-7R5G-4 |
7.5 |
25 |
18.5 |
2~15(8) |
GD100-011G-4 |
11 |
32 |
25 |
2~15(8) |
GD100-015G-4 |
15 |
40 |
32 |
2~8(4) |
Remarks
1. The input current is tested when no reactor and 380V input voltage
2. The output current is defined as the rated value when the output voltage is 380V. The output current needs to be calculated when the output voltage is 400V, 415V or 440V.
Product Specifications
Function |
Specification |
|
Power input |
Input voltage (V) |
AC 3PH 400V±15% |
Input current (A) |
Refer to the rated value |
|
Input frequency (Hz) |
50Hz or 60Hz Allowed range: 47~63Hz |
|
Power output |
Output voltage (V) |
0~input voltage |
Output current (A) |
Refer to the rated value |
|
Output power (kW) |
Refer to the rated value |
|
Output frequency (Hz) |
0~400Hz |
|
Technical control feature |
Control mode |
V/F, sensorless vector control |
Motor type |
Asynchronous motor |
|
Adjustable-speed ratio |
Asynchronous motor 1:100 (SVC) |
|
Speed control accuracy |
+-0.2% (sensorless vector control) |
|
Speed fluctuation |
+- 0.3% (sensorless vector control) |
|
Torque response |
<20ms (sensorless vector control) |
|
Torque control accuracy |
10%(sensorless vector control) |
|
Starting torque |
0.25Hz/150%(sensorless vector control) |
|
Overload capability |
150% of rated current: 1 minute |
|
Running control feature |
Frequency setting method |
Digital setting, analog setting, pulse frequency setting, multi-stage speed running setting, simple PLC setting, PID setting, MODBUS communication setting Realize the shifting between the set combination and set channel. |
Auto-adjustment of the voltage |
Keep a stable voltage automatically when the grid voltage transients |
|
Fault protection |
Provide over 30 fault protection functions: over current, Over voltage, under voltage, overheating, phase loss and overload, etc. |
|
Restart after rotating speed tracking |
Realize the smooth starting of the rotating motor |
|
Peripheral interface |
Terminal analog input resolution |
Not above 20mV |
Terminal switch input resolution |
Not above 2ms |
|
Analog input |
1 channels (AI2) 0~10V/0~20mA and 1 channel (AI3) - 10~10V |
|
Analog output |
2 channels (AO1, AO2) 0~10V /0~20mA |
|
Digital input |
4 channels common input, the Max. frequency: 1kHz, internal impedance:3.3kΩ; 1 channel high speed input, the Max. frequency: 50kHz |
|
Relay output |
2 channels programmable relay output RO1A NO, RO1B NC, RO1C common terminal RO2A NO, RO2B NC, RO2C common terminal Contactor capability: 3A/AC250V |
|
Others |
Mountable method |
Wall mountable and flange mountable |
Temperature of the running environment |
-10~500C, derate above 400C |
|
Average non-fault time |
2 years (250C ambient temperature) |
|
Protective degree |
IP20 |
|
Cooling |
Cooling |
|
Braking unit |
Embedded |
|
EMC filter |
Built-in C3 filter: meet the degree requirement of IEC61800-3 C3 External filter:meet the degree requirement of IEC61800-3 C2 |
Wiring
There are currently no product reviews.