FX2N-5A Special function blocks new
- Model: FX2N-5A
- Shipping Weight: 1Kg
- In Stock:10
- Manufactured by: Mitsubishi
FX2N-5A Special function blocks new |
Introduction
The FX2N-5A analog special function block has four input channels and one output channel.
The input channels receive analog signals and converts them to the comparable digital values.
The output channel takes a digital value and outputs an equivalent analog signal.
1, Analog signal inputs can be selected from either voltage or current input. The applicable analog signal input is set using the TO instruction supplied by the PLC main unit.
This PLC instrution is used to select different analog input signal types for each corresponding channel.
2,The FX2N-5A can be connected to FX0N/FX1N/FX2N/FX2NC/FX3G/FX33GC/FX3U/FX3UC series PLC
3, Up to 2 FX2N-5A units can be connected to FX0N main unit, FX0N extension unit, Fx1N ,main unit.
Power supply specifications
Item |
Specifications |
Interface driving power supply |
24VDC+-10%, 90mA (maximum), externally Supplied |
CPU driving power supply |
5VDC, 70mA, supplied via extension cable from PLC main unit |
Perfomance specifications
Item |
specifications |
Conversion Speed |
Channel for voltage/current input: 1ms x Number of used channels Channel for voltage/current output: 2ms (See BFM 25) |
Insulation Method |
Photocoupler insulates the annlog input/output area from PLC. DC/DC converter insulates the power supply from analog I/O. Channels are not insulated against each other |
Number of occupied I/O points |
8 points (including input and output points0 |
Applicable PLC |
FX0N, FX1N. FX2N, FX2NC, FX3G, FX3GC, FX3U, FX3UC Series PLC For connection to the FX2NC Series PLC, an FX2NC-CNV-IF is required. For connection to the FX3GC/FX3UC Series PLC, an FX2NC-CNV-IF or FX3UC-1PS-5V is required |
Built-in memory |
EEPROM |
External Dimensions and Parts
There are currently no product reviews.