FX2N-128MR-001 PLC Main Unit DI 64 DO 64 Relay AC 220V new

  • Model: FX2N-128MR-001
  • Shipping Weight: 2Kg
  • In Stock:10
  • Manufactured by: Mitsubishi
Qty:          Favorite

Payment method Shipping method Contact us


0 reviews


FX2N-128MR-001  PLC Main Unit DI 64 DO 64 Relay AC 220V new

General Specifications [Main Unit]

Item

Ambient 

temperature

Ambient temperature

0 to 55°C (32 to 131°F) when operating and -25 to 75°C (-13 to 167°F) when stored

Ambient humidity

5 to 95%RH (no condensation) when operating

Vibration resistance

Conforms to EN 68-2-6

 

Frequency

(Hz)

Acceleration

(m/s

2

)

Half 

amplitude

(mm)

Sweep Count 

for X, Y, Z: 10 

times 

(80 min in 

each direction)

When 

installed 

on DIN 

rail

10 to 57

--

0.035

57 to 150

4.9

--

When

installed

directly

10 to 57

--

0.075

57 to 150

9.8

--

Shock resistance

Compliant with EN 68-2-27

(147 m/s2Acceleration, Action time: 11ms, 3 times by

half-sine pulse in each direction X, Y, and Z)

Noise resistance

By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 µs, rise time of 1 ns and period of 30

to 100 Hz

Dielectric withstand voltage*1

 

1.5kV AC for one minute

Compliant with JEM-1021 Between each terminals*1 and ground terminal

500V AC for one minute

Insulation resistance*1

5M

500V DC megge

Grounding

Class D grounding (grounding resistance: 100 

less) <Common grounding with a heavy electrical

system is not allowed.>*2

Working atmosphere

Free from corrosive or flammable gas and excessive conductive dusts

Working altitude

Compliant with IEC61131-2 (<2000m)*3

*1

Terminal

Dielectric strength

Insulation resistance

Between power supply 

terminal (AC power) and 

ground terminal

1.5 kV AC for 

one minute

5M

500V DC megger

Between power supply 

terminal (DC power) and 

ground terminal

500V AC for 

one minute

Between input terminal 

(24V DC) and ground 

terminal

500V AC for 

one minute

Between output terminal 

(relay) and ground 

terminal

1.5 kV AC for 

one minute

Between output terminal 

(transistor) and ground 

terminal

500V AC for 

one minute

For dielectric with stand voltage test and insulationresistance test of each product, refer to the following manual.

→ Refer to FX3U Series User's Manual - Hardware Edition.

*2 For common grounding, refer to section 3.3.

*3 The PLC cannot be used at a pressure higher than the atmospheric pressure to avoid damage.

There are currently no product reviews.

1 2 3 4 5
Five Stars
NOTE: HTML tags are not allowed.
NOTE: Reviews require prior approval before they will be displayed