FRN200F1S-4C FRENIC-VP 400V Three-phase 3phase 360A 200KW Inverter VFD frequency AC drive
- Model: FRN200F1S-4C
- Shipping Weight: 106Kg
- In Stock:20
- Manufactured by: Fuji
FRENIC-VP 400V 3 phase 360A 200KW FRN200F1S-4C Inverter
Features
1. The effect of energy saving has updated again.
2. Simple structure, convenient manufacturing.
3. Durable design-10 years using life.
4. Fit with the HVAC (Hole Ventilator Air conditioner).
5. The design is fully considering the ambient and controlled board.
6. Easy operating
Standard Specifications
Three-phase 400V Series
3.7~55KW
Item |
Specifications |
||||||||||||
Type(FRNxxxF1S-4Cxxx) |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
||
Nominal applied motor [KW] |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
||
Output ratings |
Rated capacity[KVA] |
6.8 |
9.5 |
12 |
17 |
22 |
28 |
33 |
44 |
54 |
64 |
77 |
|
Rated voltage[V] |
Three-phase 380 to 480V(with AVR) |
||||||||||||
Rated Current[A] |
9.0 |
12.5 |
16.5 |
23 |
30 |
37 |
44 |
59 |
72 |
85 |
105 |
||
Rated Overload capability |
120% for 1min |
||||||||||||
Rated frequency[Hz] |
50,60Hz |
||||||||||||
Input Rating |
Rated current[A] |
With DCR |
7.5 |
10.6 |
14.4 |
21.1 |
28.8
|
35.5 |
42.2 |
57.0 |
68.5 |
83.2 |
102
|
Without DCR |
13.0 |
17.3 |
23.2 |
33.0 |
43.8 |
52.3 |
60.6 |
77.9 |
94.3 |
114 |
140 |
||
Required power supply capacity[KVA] |
With DCR |
5.3 |
7.4 |
10 |
15 |
20 |
25 |
30 |
40 |
48 |
58 |
71 |
|
Braking |
Torque[%] |
20 |
10 to 15 |
||||||||||
DC injection braking |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
||||||||||||
DC reactor (DCR) |
Optional |
||||||||||||
Applicable safety standards |
UL508C, C22.2No.14, EN50178: 1997 |
||||||||||||
Enclosure (IEC60529) |
IP20 (IEC60529) closed type, UL open type |
IP00 open type, UL open type |
|||||||||||
Cooling method |
Fan cooling |
||||||||||||
Weight/Mass[kg] |
3.4 |
3.4 |
5.8 |
6.0 |
6.9 |
9.4 |
9.9 |
11.5 |
23 |
24 |
33 |
7.5~560KW
Item |
Specifications |
|||||||||||||||
Type(FRNxxxF1S-4Cxxx) |
75 |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
450 |
500 |
560 |
||
Nominal applied motor [KW] |
75 |
90 |
110 |
132 |
160 |
200 |
220 |
280 |
315 |
355 |
400 |
450 |
500 |
560 |
||
Output ratings |
Rated capacity[KVA] |
105 |
128 |
154 |
182 |
221 |
274 |
316 |
396 |
445 |
495 |
563 |
640 |
731 |
792 |
|
Rated voltage[V] |
Three-phase 380 to 480V(with AVR) |
|
|
|
||||||||||||
Rated Current[A] |
139 |
168 |
203 |
240 |
290 |
360 |
415 |
520 |
585 |
650 |
740 |
840 |
960 |
1040 |
||
Rated Overload capability |
120% for 1min |
|||||||||||||||
Rated frequency[Hz] |
50,60Hz |
|||||||||||||||
Input Rating |
Rated current[A] |
With DCR |
138 |
164 |
201 |
238 |
286
|
357 |
390 |
500 |
559 |
628 |
705
|
789 |
881 |
990 |
Without DCR |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
||
Required power supply capacity[KVA] |
With DCR |
96 |
114 |
140 |
165 |
199 |
248 |
271 |
347 |
388 |
435 |
489 |
547 |
611 |
686 |
|
Braking |
Torque[%] |
10 to 15 |
||||||||||||||
DC injection braking |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
|||||||||||||||
DC reactor (DCR) |
Standard |
|||||||||||||||
Applicable safety standards |
UL508C, C22.2No.14, EN50178: 1997(applying) |
|||||||||||||||
Enclosure (IEC60529) |
IP00 open type, UL open type |
|||||||||||||||
Cooling method |
Fan cooling |
|||||||||||||||
Weight/Mass[kg] |
34 |
42 |
45 |
63 |
67 |
96 |
98 |
162 |
165 |
282 |
286 |
355 |
360 |
360 |
There are currently no product reviews.