FR-F720-22K FR-F700 VFD Inverter input 3 phase 220V output 3 ph 200~240V 72A 22KW 0.5~400Hz with keypad new

  • Model: FR-F720-22K
  • Shipping Weight: 14Kg
  • In Stock:20
  • Manufactured by: Mitsubishi
Qty:          Favorite

Payment method Shipping method Contact us


0 reviews


FR-F720-22K

FR-F720-22K model

Specification

Type FR-F720- K

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

Applicable motor capacity

(kW)*1

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

Output

Rated capacity (kVA)*2

1.6

2.7

3.7

5.8

8.8

11.8

17.1

22.1

27

32

43

53

65

81

110

132

165

Rated current (A)*3

4.2(3.6)

7.0(6.0)

9.6(8.2)

15.2(13)

23(20)

31(26)

45(38)

58(49)

70(60)

85(72)

114(97)

140(119)

170(145)

212(180)

288(248)

346(294)

432(367)

Overload current

rating*4

120% for 60s, 150% for 3s (inverse time characteristics)

Voltage*5

Three-phase 200 to 240V

Power supply

Rated input AC

voltage/frequency

Three-phase 200 to 220V 50Hz, 200 to 240V 60Hz

Permissible AC

voltage fluctuation

170 to 242V 50Hz, 170 to 264V 60Hz

Permissible frequency

fluctuation

±5%

Power

supply

system

capacity

(kVA)*6

Without DC

reactor

2.1

4.0

4.8

8.0

11.5

16

20

27

32

41

52

65

79

99

-

-

-

With DC

reactor

1.2

2.6

3.3

5.0

8.1

10

16

19

24

31

41

50

61

74

110

132

165

Protective structure

(JEM 1030)*8

Enclosed type (IP20)*7

Open type (IP00)

Cooling system

Selfcooling

Forced air cooling

Approx. mass (kg)

1.8

2.2

3.5

3.5

3.5

6.5

6.5

7.8

13

13

14

23

35

35

67

70

70

*1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

*2 The rated output capacity indicated assumes that the output voltage is 220V.

*3 When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter

output current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.

*4 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated

duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.

*5 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting

range. However, the pulse voltage value of the inverter output side voltage remains unchanged at about that of the power supply.

*6 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and

cables).

*7 When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type ().

*8 FR-DU07: IP40 (except for the PU connector)

Dimensions

FR-F720-22K dimensions

There are currently no product reviews.

1 2 3 4 5
Five Stars
NOTE: HTML tags are not allowed.
NOTE: Reviews require prior approval before they will be displayed