FR-D720S-1.5K-CHT FR-D700 VFD Inverter input 1 phase 220V output 3 ph 200~240V 7A 1.5KW 0.2~400Hz with keypad new

  • Model: FR-D720S-1.5K-CHT
  • Shipping Weight: 2.5Kg
  • In Stock:20
  • Manufactured by: Mitsubishi
Qty:          Favorite

Payment method Shipping method Contact us


0 reviews


FR-D720S-1.5K-CHT

FR-D720S-1.5K-CHT model

 

Specification

Model FR-D720S- K(-C)6

0.1

0.2

0.4

0.75

1.5

2.2

Applicable motor capacity(kW) 1

0.1

0.2

0.4

0.75

1.5

2.2

Output

Rated capacity(kVA) 2

0.3

0.6

1.0

1.7

2.8

4.0

Rated current(A)

0.8

1.4

2.5

4.2

7.0

10.0

Overload current ranting3

150% 60s, 200% 0.5s (inverse-time characteristics)

Voltage4

Three-phase 200 to 240V

Power supply

Rated input AC voltage/frequency

Single-phase 200 to 240V 50Hz/60Hz

Pemnissible AC voltage fluctuation

170 to 264V 50Hz/60Hz

Pemnissible frequency fluctuation

±5%

Power supply capacity (kVA) 5

0.5

0.9

1.5

2.3

4.0

5.2

Protective structure(JEM1030)

Enclosed type (IP20).

Cooling system

Self-cooling

Forced air cooling

Approximate mass (kg)

0.5

0.5

0.9

1.1

1.5

2.0

1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

2 The rated output capacity indicated assumes that the output voltage is 230V.

3 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for

the inverter and motor to return to or below the temperatures under 100% load. If the automatic restart after instantaneous power failure function (Pr. 57) or

power failure stop function (Pr. 261) is set and power supply voltage is low while load becomes bigger, the bus voltage decreases to power failure detection

level and load of 100% or more may not be available.

4 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,

the pulse voltage value of the inverter output side voltage remains unchanged at about that of the power supply.

5 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).

6 For single-phase 100V power input model, the maximum output voltage is twice the amount of the power supply voltage and cannot be exceeded.

7 For single-phase 100V power input model, output voltage decreases 10 to 15% approximately by applying motor load. The load must be reduced for an

operation with a general-purpose motor

Dimensions

 

FR-D720S-1.5K-CHT dimensions

There are currently no product reviews.

1 2 3 4 5
Five Stars
NOTE: HTML tags are not allowed.
NOTE: Reviews require prior approval before they will be displayed