FR-D720-0.75K FR-D700 VFD Inverter input 3 phase 220V output 3 ph 200~240V 4.2A 0.75KW 0.2~400Hz with keypad new
- Model: FR-D720-0.75K
- Shipping Weight: 2Kg
- In Stock:20
- Manufactured by: Mitsubishi
FR-D720-0.75K
Specification
Model FR-D720- K(-C)6 |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
|
Applicable motor capacity(kW) 1 |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
|
Output |
Rated capacity(kVA) 2 |
0.3 |
0.6 |
1.0 |
1.7 |
2.8 |
4.0 |
6.6 |
9.5 |
12.7 |
Rated current(A) |
0.8 |
1.4 |
2.5 |
4.2 |
7.0 |
10.0 |
16.5 |
23.8 |
31.8 |
|
Overload current ranting3 |
150% 60s, 200% 0.5s (inverse-time characteristics) |
|||||||||
Voltage4 |
Three-phase 200 to 240V |
|||||||||
Power supply |
Rated input AC voltage/frequency |
Three-phase 200 to 240V 50Hz/60Hz |
||||||||
Pemnissible AC voltage fluctuation |
170 to 264V 50Hz/60Hz |
|||||||||
Pemnissible frequency fluctuation |
±5% |
|||||||||
Power supply capacity (kVA) 5 |
0.4 |
0.7 |
1.2 |
2.1 |
4.0 |
5.5 |
9.0 |
12.0 |
17.0 |
|
Protective structure(JEM1030) |
Enclosed type (IP20). IP40 for totally enclosed structure series. |
|||||||||
Cooling system |
Self-cooling |
Forced air cooling |
||||||||
Approximate mass (kg) |
0.5 |
0.5 |
0.8 |
1.0 |
1.4 |
1.4 |
1.8 |
3.6 |
3.6 |
1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
2 The rated output capacity indicated assumes that the output voltage is 230V for three-phase 200V class and 440V for three-phase 400V class.
3 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for
the inverter and motor to return to or below the temperatures under 100% load.
4 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However,
the pulse voltage value of the inverter output side voltage remains unchanged at about that of the power supply.
5 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
6 Totally enclosed structure series ends with -C.
Dimensions
There are currently no product reviews.