DVPPF02-SL Delta S Series PLC Left-Side High-Speed Communication Module new in box

  • Model: DVPPF02-SL
  • Shipping Weight: 1Kg
  • In Stock:20
  • Manufactured by: Delta
Qty:          Favorite

Payment method Shipping method Contact us


0 reviews


DVPPF02-SL Delta S Series PLC Left-Side High-Speed Communication Module new in box

Introduction to DVPPF02-SL

1. Thank you for choosing Delta DVPPF02-SL PROFIBUS DP slave communication module. To ensure correct installation and operation of the product, please read this operation manual carefully before using it.

2. This operation manual only provides introductory information on DVPPF02-SL. For more detailed information on the PROFIBUS DP protocol, please refer to relevant references or literatures.

3. DVPPF02-SL is a PROFIBUS DP slave communication module, used for connecting the Delta DVP-SV and DVP-SX2 series PLC to the PROFIBUS DP network. DVPPF02-SL is a left-side extension module, and no external power supply is required when using it. The power is supplied by the PLC MPU (main processing unit).

Features

1. Supports the loop data transmission between the PROFIBUS DP master and many slaves.

2. Auto-detects baudrate; supports max. 12M bps. Self-diagnosis

3. A PLC MPU is extendable to max. 8 modules on its left hand side.

4. Supports max. 100 words of I/O output and 100 words of I/O input.

Specifications

PROFIBUS DP Port

Interface

DB9 connector

Transmission method

High-speed RS-485

Transmission cable

Shielded twisted pair cable

Electrical isolation

500 VDC

Communication

Data type

Cyclic data exchange

Module name

DVPPF02-SL

GSD document

DELA0AFE.GSD

Product ID

0AFE

Serial baudrate

supported

(auto-detection)

9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps

(bits/second)

Electrical Specification

Power supply voltage

24 VDC

Insulation voltage

500 VDC

Power consumption

2 W

Weight

115g

Environment

Interference immunity

ESD (IEC 61800-5-1, IEC 6100-4-2)

EFT (IEC 61800-5-1, IEC 6100-4-4)

Surge Teat (IEC 61800-5-1, IEC 6100-4-5)

Conducted Susceptibility Test (IEC 61800-5-1, IEC 6100-4-6)

Storage/operation

Operation: -10 to 50°C (temperature), 90% (humidity)

Storage: -25 to 70°C (temperature), 95% (humidity)

Shock/vibration

immunity

International standards: IEC 61800-5-1, IEC 60068-2-6/IEC 61800-5-1,

IEC 60068-2-27

 