CP1W-CIF41 PLC Ethernet Expansion new in box
- Model: CP1W-CIF41
- Shipping Weight: 0.5Kg
- In Stock:20
- Manufactured by: Omron
CP1W-CIF41 PLC Ethernet Expansion new in boxFeatures:
Pulse Outputs
Up to Four Axes Are Standard.
Advanced Power for High-precision Positioning Control.
Positioning for Electronic Component Manufacturing Equipment
Sheet Feeding for Vertical Pillow Packer
Pulse Output Function for Up to Four Axes.
Along with greater precision and more flexibility in multi-product manufacturing, high-speed multi-axis pulse output control responds to the increase in servo applications.
High-speed Counters
Differential Phases for Up to Four Axes Are Standard.
Easily Handles Multi-axis Control with a Single Unit.
Main-axis Control for Equipment Such as Textile Machinery or Spinning Machinery
Positioning Conveyance for Equipment Such as Building Material Manufacturing Machinery and Stone-cutting Machinery
Specification:
Item |
Specification |
|
Number of nodes |
254 |
|
Message length |
1016 bytes max (CJ1W-ENT21 is 2024bytes) |
|
Number of buffers |
8k (CJ1W-ETN21 is 392kbytes) |
|
Protocol name |
FINS/UDP method |
FINS/TCP method |
Protocol used |
UDP/IP |
TCP/IP |
The selection of UDP/IP or TCP/IP is made by means of the FINS/TCP Tab in the CX-Programmer’s Unit Setup. |
||
Number of connections |
|
2 (CJ1W-ETN21 is 16) |
Port number |
9600 (default) Can be changed. |
9600 (default) Can be changed. |
Protection |
No |
Yes (Specification of client IP addresses when unit is Protection No used as a server) |
Other |
Items set for each UDP port Broadcast Address conversion method |
Items set for each connection Server specification Remote IP address spec. Server: specify IP addresses of clients permitted to connect. Client: specify remote Ethernet Unit (server) IP address Automatic FINS node address allocation Specify automatic allocation of client FINS node addresses |
|
||
Internal table |
This is a table of correspondences for remote FINS node addresses, remote IP addresses, TCP/UDP, and remote port numbers. It is created automatically when power is turned ON to the PLC or when the unit is restarted, and it is automatically changed when a connection is established by means of the FINS/TCP method or when a FINS command received. The following functions are enabled by using this table. IP address conversion using the FINS/UDP method Automatic FINS node address conversion after a connection is established using the FINS/TCP method Automatic client FINS node address allocation using the FINS/TCP method Simultaneous connection of multiple FINS applications |