Specification
| 
 Item  | 
 Specification  | 
|||||||||||||||
| 
 Three-Phase: CIMR-V□2A  | 
 0001  | 
 0002  | 
 0004  | 
 0006  | 
 0008  | 
 0010  | 
 0012  | 
 0018  | 
 0020  | 
 0030  | 
 0040  | 
 0056  | 
 0069  | 
|||
| 
 Single-Phase: CIMR-V□BA  | 
 0001  | 
 0002  | 
 0003  | 
 0006  | 
 -  | 
 0010  | 
 0012  | 
 -  | 
 0018  | 
 -  | 
 -  | 
 -  | 
 -  | 
|||
| 
 Maximum Motor Size Allowed (kW)  | 
 ND Rating  | 
 0.2  | 
 0.4  | 
 0.75  | 
 1.1  | 
 1.5  | 
 2.2  | 
 3.0  | 
 3.7  | 
 5.5  | 
 7.5  | 
 11.0  | 
 15.0  | 
 18.5  | 
||
| 
 HD Rating  | 
 0.1  | 
 0.2  | 
 0.4  | 
 0.75  | 
 1.1  | 
 1.5  | 
 2.2  | 
 3.0  | 
 3.7  | 
 5.5  | 
 7.5  | 
 11.0  | 
 15.0  | 
|||
| 
 Input  | 
 Input Current (A)  | 
 Three-Phase  | 
 ND Rating  | 
 1.1  | 
 1.9  | 
 3.9  | 
 7.3  | 
 8.8  | 
 10.8  | 
 13.9  | 
 18.5  | 
 24.0  | 
 37.0  | 
 52.0  | 
 68.0  | 
 80.0  | 
| 
 HD Rating  | 
 0.7  | 
 1.5  | 
 2.9  | 
 5.8  | 
 7.0  | 
 7.5  | 
 11.0  | 
 15.6  | 
 18.9  | 
 24.0  | 
 37.0  | 
 52.0  | 
 68.0  | 
|||
| 
 Single-Phase  | 
 ND Rating  | 
 2.0  | 
 3.6  | 
 7.3  | 
 13.8  | 
 -  | 
 20.2  | 
 24.0  | 
 -  | 
 -  | 
 -  | 
 -  | 
 -  | 
 -  | 
||
| 
 HD Rating  | 
 1.4  | 
 2.8  | 
 5.5  | 
 11.0  | 
 -  | 
 14.1  | 
 20.6  | 
 -  | 
 35.0  | 
 -  | 
 -  | 
 -  | 
 --  | 
|||
| 
 Output  | 
 Rated Output Capacity (kVA)  | 
 ND Rating  | 
 0.5  | 
 0.7  | 
 1.3  | 
 2.3  | 
 3.0  | 
 3.7  | 
 4.6  | 
 6.7  | 
 7.5  | 
 11.4  | 
 15.2  | 
 21.3  | 
 26.3  | 
|
| 
 HD Rating  | 
 0.3  | 
 0.6  | 
 1.1  | 
 1.9  | 
 2.6  | 
 3.0  | 
 4.2  | 
 5.3  | 
 6.7  | 
 9.5  | 
 12.6  | 
 17.9  | 
 22.9  | 
|||
| 
 Output Current (A)  | 
 ND Rating  | 
 1.2  | 
 1.9  | 
 3.5  | 
 6.0  | 
 8.0  | 
 9.6  | 
 12.0  | 
 17.5  | 
 19.6  | 
 30.0  | 
 40.0  | 
 56.0  | 
 69.0  | 
||
| 
 HD Rating  | 
 0.8  | 
 1.6  | 
 3.0  | 
 5.0  | 
 6.9  | 
 8.0  | 
 11.0  | 
 14.0  | 
 17.5  | 
 25.0  | 
 33.0  | 
 47.0  | 
 60.0  | 
|||
| 
 Overload Tolerance  | 
 ND Rating: 120% of rated output current for 1 minute HD Rating: 150% of rated output current for 1 minute (Derating may be required for applications that start and stop frequently)  | 
|||||||||||||||
| 
 Carrier Frequency  | 
 2 kHz (user-set, 2 to 15 kHz)  | 
|||||||||||||||
| 
 Max Output Voltage (V)  | 
 Three-phase 200 to 240 V (proportional to input voltage)  | 
|||||||||||||||
| 
 Max Output Frequency (Hz)  | 
 400 Hz (user-adjustable)  | 
|||||||||||||||
| 
 Power Supply  | 
 Rated Voltage Rated Frequency  | 
 Three-phase power: Three-phase 200 to 240 V 50/60 Hz Single-phase power: 200 to 240 V 50/60 Hz  | 
||||||||||||||
| 
 Allowable Voltage Fluctuation  | 
 -15 to 10%  | 
|||||||||||||||
| 
 Allowable Frequency Fluctuation  | 
 ±5%  | 
|||||||||||||||
| 
 Harmonic Corrective Actions  | 
 DC Reactor  | 
 Optional  | 
||||||||||||||
There are currently no product reviews.