CIMR-HB4A0091FAA VFD inverter input 3ph 380V output 3ph 0~480V 80A 37KW 0~400Hz New
- Model: CIMR-HB4A0091FAA
- Shipping Weight: 50Kg
- In Stock:20
- Manufactured by: Yaskawa
CIMR-HB4A0091FAA VFD inverter input 3ph 380V output 3ph 0~480V 80A 37KW 0~400Hz New |
Specification
Item |
Specification |
||||||||||
CIMR-H□4A |
0045 |
0060 |
0075 |
0091 |
0112 |
0150 |
0180 |
0216 |
0260 |
||
Maximum Applicable Motor Capacity (kW) |
HD Rating |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
110 |
132 |
|
SHD Rating |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
110 |
||
Input |
Input Current (A) |
HD Rating |
43 |
58 |
71 |
86 |
105 |
142 |
170 |
207 |
248 |
SHD Rating |
36 |
43 |
58 |
71 |
86 |
105 |
142 |
170 |
207 |
||
Rated Voltage Rated Frequency |
AC:Three-Phase 380 to 480V 50/60Hz DC:510 to 680 V |
||||||||||
Allowable Voltage Fluctuation |
–15 to +10% |
||||||||||
Allowable Frequency Fluctuation |
±5% |
||||||||||
Input Power (kVA) |
HD Rating |
39 |
53 |
65 |
79 |
96 |
130 |
155 |
189 |
227 |
|
SHD Rating |
33 |
39 |
53 |
65 |
79 |
96 |
130 |
156 |
190 |
||
Output |
Rated Output Capacity (kVA) |
HD Rating |
34 |
46 |
57 |
69 |
85 |
114 |
137 |
165 |
198 |
SHD Rating |
32 |
40 |
50 |
61 |
74 |
98 |
126 |
149 |
183 |
||
Rated Output Current (A) |
HD Rating |
45 |
60 |
75 |
91 |
112 |
150 |
180 |
216 |
260 |
|
SHD Rating |
42 |
52 |
65 |
80 |
97 |
128 |
165 |
195 |
240 |
||
Overload Tolerance |
HD Rating: 150% of rated output current for 60 s SHD Rating: 150% rated output current for 60 s or 200% rated output current for 3 s Note: Derating may be required for applications that start and stop frequently. |
||||||||||
Carrier Frequency |
2 to 15 kHz (User adjustable) |
||||||||||
Maximum Output Voltage (V) |
Three-phase 380 to 480 V (proportional to input voltage) |
||||||||||
Maximum Output Frequency (Hz) |
400 Hz (user-adjustable) |
There are currently no product reviews.