BFV00152GK Inverter 230VAC 1.5KW 1 Phase New
- Model: BFV00152GK
- Shipping Weight: 4Kg
- In Stock:19
- Manufactured by: Panasonic
BFV00152GK Inverter 230VAC 1.5KW 1 Phase New |
Features
Ultra-compact
- Easy to operate using the integrated operating panel
- Cost effective
- Easy and accurate frequency control using PLC puls output
- Various types without and with brake included (1-phase)
- 8-speed control function
- Retry function
- Frequency increase, decrease and memory functions
using external switches
- Complete regeneration brake function
1-phase 230V AC Input types
MotorPower PN [kW] |
Part No. |
|
Brake |
||
provided |
not provided |
|
0.2 |
|
BFV00022DK |
0.4 |
BFV00042GK |
BFV00042DK |
0.75 |
BFV00072GK |
BFV00072DK |
1.5 |
BFV00152GK |
BFV00152DK |
3-phase 400V AC Input types
MotorPower PN [kW] |
Part No. |
0.75 |
BFV00074 |
1.5 |
BFV00154 |
2.2 |
BFV00224 |
3.7 |
BFV00374 |
Specifications
Input voltage |
1-phase 230V AC |
3-phase 400V AC |
|
Applied motor output |
0.2 to 1.5kW |
0.75 to 3.7kW |
|
Rated Output |
Rated output voltage |
3-phase 200 to 230V AC (proportional to power supply voltage) |
3-phase 380 to 460V AC (proportional to power supply voltage) |
Overload current rating |
150% of rated output current for 1 minute |
||
Input Power Supply |
Phases, voltage, frequency |
1-phase 200 to 230V AC 50/60Hz |
3-phase 380 to 460V AC 50/60Hz |
Tolerable voltage variations |
+10%, –15% of rated AC input voltage |
||
Tolerable frequency variations |
+-5% of rated input frequency |
||
Instantaneous voltage drop resistance capacity |
Continuous operation at 165V or more. Continuous operation at less than 165V for 15ms |
Continuous operation at 323V or more. Continuous operation at less than 323V for 15ms |
|
Output Frequency |
Output frequency range |
0.5 to 250Hz |
|
Frequency display |
Frequency display |
||
Frequency accuracy |
+-0.5% of selected maximum set frequency (25+-10°C) for analogue setting |
||
Frequency setting resolution |
Digital setting: 0.1Hz (1Hz over 100Hz), Analogue setting: 0.1Hz (50/60Hz mode) |
||
Inverter control method |
High carrier frequency sinusoidal PWM control (V/F control method) |
||
Carrier frequency |
Select from 9 types (The output current must be reduced for 12.5 and 15.0kHz) (0.8, 1.1, 1.6, 2.5, 5.0, 7.5, 10, 12.5, 15kHz |
Select from 7 types (0.8, 1.1, 1.6, 2.5, 5.0. 7.5, and 10kHz) (The output current of 3.7kW must be reduced when set to 10kHz.) |
|
Operation |
Start/Stop |
Operation panel buttons or input contact signal (wait time setting possible) |
|
Forward/Reverse |
Operation panel buttons or input contact signal (reverse rotation prohibit setting possible) |
||
Jog operation |
Operating frequency: Optional setting for 0.5 to 250Hz, Acceleration/deceleration time: Optional setting each for 0.04 to 999 seconds |
||
Stop mode |
Select from ramp-to-stop or coast-to-stop (selection changeover |
||
Reset function |
Stop signal reset, external reset, panel reset (setting possible) and power supply reset |
||
Stop frequency |
Optional setting from 0.5 to 60Hz |
||
Instantaneous power failure restart |
Function OFF, and 0Hz restart, operating frequency restart (selection changeover) |
||
Retry function |
Retry selection: Select function OFF and details of retry fault, No. of retries: Optional setting for 1 to 10 times |
||
Control |
Frequency setting signal |
Local setting: Potentiometer, digital setting (operation panel) External analog setting signal: Potentiometer (10kW, 1/4 or more), 0 to 5V, 0 to 10V, 4 to 20mA (Connect a 200 , 1/4W or more external resistor) External digital setting signal: PWM signal (signal cycle: 0.9 to 1100ms), Frequency up SW, down SW, save SW signal |
|
Voltage/frequency characteristics |
Base frequency: 50, 60Hz fixed and optional setting between 45 and 250Hz V/F curve: Constant torque, square torque pattern (selection changeover |
||
2nd voltage/frequency characteristics |
Optional base frequency setting for 45 to 250Hz |
||
1st and 2nd torque boost level |
Optional setting for 0 to 40% |
||
1st and 2nd accel./Decel. Time |
0.04 to 999sec. (individual accel. and decel. Time setting), Accel./Decel. Characteristics: Linear |
||
Multi-speed frequency setting |
Up to 8 preset frequency settings (optional setting) |
||
Skip frequency setting |
Up to 3 place settings (skip frequency band setting from 1 to 10Hz) |
||
Upper and lower frequency setting |
Optional setting from 0.5 to 250Hz |
||
Bias/gain frequency settings |
Bias frequency: set from –99 to 250Hz, Gain frequency: set from 0 to 250Hz |
||
External stop function |
Select from auxiliary stop or coast-to-stop (selection setting |
There are currently no product reviews.