ASD-B2-1021-B Detla AC Sevor Drive 1phase 220V 1KW 7.3A New original
- Model: ASD-B2-1021-B
- Shipping Weight: 2.5Kg
- In Stock:20
- Manufactured by: Delta
Specifications of Servo Drive
Model |
ASD-B2-1021-B |
|||
Corresponding Servo Motor |
ECMA-C_1010_S (S = 22mm) ECMA-C_0910_S(S=16mm) ECMA-E_1310_S (S=22mm) ECMA-F_1308_S(S=22mm) ECMA-G_1309_S(S=22mm) ECMA-GM1309PS(PS=22mm) |
|||
Power |
1000W |
|||
Power |
Phase / Voltage |
Single-phase: 200 ~ 255 VAC, 50/60Hz ±5 % |
||
Continuous Output Current |
7.3Arms |
|||
Cooling method |
Fan cooling |
|||
Encoder Resolution (Servo Drive Resolution) |
17-bit (160000 p/rev) |
|||
Main Circuit Control |
SVPWM (Space Vector Pulse Width Modulation) Control |
|||
Control Mode |
Manual/ Auto |
|||
Regenerative Resistor |
Built-in |
|||
Position Control Mode |
Max. Input Pulse Frequency |
Line driver:500k(low-speed)/4 Mpps(high-speed) Open collector:200Kpps |
||
Pulse Type |
Pulse +Symbol, A phase + B phase, CCW pulse + CW pulse |
|||
Command Source |
External pulse |
|||
Smoothing Strategy |
Low-pass filter |
|||
E-gear ratio |
E-gear ratio N/M time(s) The limit is: (1/50 < N/M < 25600) |
|||
Torque Limit |
Parameter settings |
|||
Feed Forward Compensation |
Parameters settings |
|||
Speed Control Mode |
Analog Command Input |
Voltage Range |
0 ~ ±10 VDC |
|
Input Resistance |
10 K ohm |
|||
Time Constant |
2.2 us |
|||
Speed Control Range*1 |
1 : 5000 |
|||
Command Source |
External analog command / Register |
|||
Smoothing Strategy |
Low-pass and S-curve filter |
|||
Torque Limit |
Via parameter setting or analog input |
|||
Bandwidth |
Maximum 550 kHz |
|||
Speed Accuracy*2 |
0.01% or less at 0 to 100% load fluctuation |
|||
0.01% or less at ±10% power fluctuation |
||||
0.01% or less at 0 to 50 degree centigrade ambient temperature fluctuation |
||||
Torque Control Mode |
Analog Command Input |
Voltage Range |
0 ~ ±10 VDC |
|
Input Resistance |
10 K ohm |
|||
Time Constant |
2.2 us |
|||
Command Source |
External analog command / Register |
|||
Smoothing Strategy |
Low-pass filter |
|||
Speed Limit |
Via parameter setting or analog input |
|||
Analog Monitor Output |
Monitor signal can set by parameters (Output voltage range: ±8 V) |
|||
Communication Interface |
RS-232 / RS-485 |
There are currently no product reviews.