ASD-A2-2043-M 3phase 400V 2KW 6.66A with Full-Closed Control Delta AC Servo Drive New

  • Model: ASD-A2-2043-M
  • Shipping Weight: 4Kg
  • In Stock:20
  • Manufactured by: Delta
Qty:          Favorite

Payment method Shipping method Contact us


0 reviews


 

 

Model

ASD-A2-2043-M

Corresponding Servo Motor

ECMA-J11020 _S(S=22mm)

ECMA-K11320_S(S=22mm)

ECMA-K11820_S(S=35mm)

 power

2KW

Power

Input Voltage

24VDC,+/- 10%

Input Current

1.18A

Input Power

28.2W

Main Circuit Power

Three-phase

380 ~ 480 VAC, +/- 10%

Continuous Output Current

6.66Arms

Cooling method

Fan cooling

Encoder Resolution  (Servo Drive Resolution)

Incremental type: 20-bit (1280000 p/rev) ;Absolute type: 17-bit (1280000 p/rev)

Main Circuit Control

SVPWM (Space Vector Pulse Width Modulation) Control

Control Mode

Auto / Manual

Dynamic Brake

External

Position

Control

Mode

Max. Input Pulse

Frequency

Max. 500Kpps / 4Mpps (Line driver), Max. 200Kpps (Open collector)

Pulse Type

Pulse + Direction, A phase + B phase, CCW pulse + CW pulse

Command Source

External pulse train /Internal parameters

Smoothing Strategy

Low-pass and P-curve filter

E-gear ratio

E-gear ratio N/M multiple N: 1~32767, M: 1:32767 (1/50 < N/M < 25600)

Torque Limit

Parameter settings

Feed Forward Compensation

Parameters settings

Speed

Control

Mode

Analog

Command

Input

Voltage

Range

0 ~ ±10 VDC

Input

Resistance

10 K Ω

Time

Constant

2.2 us

Speed Control Range

1 : 5000

Command Source

External analog command / Register

Smoothing Strategy

Low-pass and S-curve filter

Torque Limit

Via parameter setting or analog input

Bandwidth

Maximum 1 kHz

Speed Accuracy

0.01% or less at 0 to 100% load fluctuation

0.01% or less at ±10% power fluctuation

0.01% or less at 0°C to 50°C ambient temperature fluctuation

Torque

Control

Mode

Analog

Command

Input

Voltage

Range

0 ~ ±10 VDC

Input

Resistance

10 KΩ

Time

Constant

2.2 us

Command Source

External analog command / Register

Smoothing Strategy

Low-pass filter

Speed Limit

Via parameter setting or analog input

Analog Monitor Output

Monitor signal can set by parameters (Output voltage range: ±8 V)

Communication Interface

RS-232 / RS-485 / CAN open/USB

 

 